Owner`s manual

Owner’s Manual – Prodigy 3
16
H1250 1250 Rev. I
This Dux water heater is designed such
that there is little to do regarding system
maintenance other than that detailed in
this Owner’s Manual.
Personally inspecting or servicing any
part of the system is not recommended.
After each 5 years of operation you
should contact the local service agent
to replace all safety valves and anodes
to ensure continued system life and
operational safety. In locations where
the water has a TDS greater than 600
ppm, this service is recommended each
3 years.
Six Monthly Service – By Owner
Operate the Pressure & Temperature
Relief Valve for approximately 10 seconds
by operating the easing lever on the
valve to ensure water is relieved to waste
through the relief drain pipe. Check to
ensure the valve closes correctly.
Five Year Service – By Authorised
Personnel Only
The ve year service must be carried
out by a licensed tradesperson. It is
recommended that this service be
carried out by your local Dux agent.
The service should include the following:
Replace the Pressure &
Temperature Relief Valve.
Replace the anodes (in areas of
harsh or adverse water conditions, a
more frequent check of the anodes
is recommended).
Flush the water heater by doing the
following:
i. Turn off gas and electricity
supply.
ii. Turn off the cold water supply to
the water heater at the isolating
valve.
iii. Gently operate the easing lever
on the Pressure & Temperature
Relief Valve to release the
pressure in the water heater.
iv. Disconnect the cold water inlet
union to the heater and attach a
drain hose.
v. Gently operate the Pressure
& Temperature Relief Valve to
let air into the heater and allow
water to escape through the
hose.
vi. Flush the heater until clear water
appears then reconnect all
ttings, ll the heater and restore
the gas and electricity supply.
System Maintenance