Manual

dis-
ther
he
imal
ects
s of
. If
dis-
ween
onds
ions
ram
acti-
mul-
or
ec-
keys
menu
has
arm.
ous-
Page 9
ing the control (similar to turning power off and on). ‘Global Reset’ will allow recov-
ery from errors and reset the following menu items:
AL i.H: Alarm inhibit 0PEn 1nP: Input error
bA nP: Input err CHEC CAL: Check calibration
Correct the problems associated with the above conditions before using the reset
keys. More than one error could present. Caution is advised since several items are
reset at one time.
While in the Primary or Secondary Menu, if no key is pressed for a period of 30
seconds, the display will return to the HOME position displaying the temperature
value. While in the Secure Menu, if no key is pressed for a period of 60 seconds,
the display will return to HOME position displaying the temperature value. Outputs
are disabled (turned off) when the Secure Menu is active.
NOTE: To move the Primary Menu quickly from any other menu, press the
UP ARROW & ENTER keys followed by pressing the INDEX &
DOWN ARROW keys.
SECURITY LEVEL SELECTION
Four levels of security are provided. The display shows the current security level. To
change security levels, change the password value using the UP ARROW and
DOWN ARROW keys and press the ENTER key. Refer to the password
table for the correct value to enter for the security level desired. The SECr menu
item security level may be viewed or changed at any time regardless of the present
security level.
Example: To set security access level to 2, at the SECr menu item, press the
UP ARROW key until the upper display shows the password for level 2 access,
1101. Press the ENTER key. The display will blink and return with the level
value, 2, in the upper display.
The password values shown in the table cannot be altered, so retain a copy of
these pages for reference. This is the only reference made to password values in
this intruction book.
949-1265:Layout 1 1/25/11 10:22 AM Page 9