Submittal Sheet

1/2 NPT
2-11/64
[55.17]
8-61/64
[227.30]
2-41/64
[67.03]
2-9/64
[54.37]
3-11/64
[80.57]
35/64
[13.89]
2-9/16
[64.96]
2-11/64
[55.12]
[3] 3/16 [4.76] HOLES
EQUALLY SPACED
ON A 4.115 [104.52] BC
A-RHP-FC
HUMIDITY/TEMPERATURE TRANSMITTERS
Passive Temperature Outputs, Sintered Filter Options
The Series RHP Humidity/Temperature Transmitters combine the voltage or
current humidity transmitter output with a passive temperature thermistor or RTD
output. Featuring polymer capacitance humidity sensors, models are available with
2%, 3% or 5% accuracies. Duct mounted transmitters are available with an optional
two-line alpha numeric LCD display.
FEATURES/BENEFITS
2%, 3%, or 5% accuracy models
Optional LCD display on duct mount models
Radiation shield option for outdoor installation in direct sunlight
APPLICATIONS
Air economizers
Outdoor temperature and relative humidity reference
Pool room humidity monitoring
SPECIFICATIONS
Relative Humidity Range: 0 to 100% RH.
Temperature Range: -40 to 140°F (-40 to 60°C).
Accuracy, RH: RHP-2XXX ±2% 10-90% RH @ 25°C; RHP-3XXX ±3% 20-80% RH
@ 25°C; RHP-5XXX ±5% 20-80% RH @ 25°C.
Accuracy, Thermistor Temp Sensor: ±0.2°C @ 25°C (±0.36°F @ 77°F).
Accuracy, RTD Temp Sensor: DIN Class B; ±0.3°C @ 0°C (±0.54°F @ 32°F).
Accuracy, Solid State Band Gap: ±0.9°F @ 77°F (±0.3°C @ 25°C).
Hysteresis: ±1%.
Repeatability: ±0.1% typical.
Temperature Limits: -40 to 140°F (-40 to 60°C).
Storage Temperature: -40 to 176°F (-40 to 80°C).
Compensated Temperature Range: -4 to 140°F (-20 to 60°C).
4-20 mA Loop Powered Models: Power requirements: 10-35 VDC; Output signal:
4-20 mA.
0-5/10 V Output Models: Power requirements: 15-35 VDC or 15-29 VAC; Output
signal: 0-10 V @ 5 mA max.
Solid State Band Gap Temperature Sensor Output Ranges: Switch selectable,
-20 to 140°F (-28.9 to 60°C); 0 to 100°F (-17.8 to 37.8°C); 40 to 90°F (4.4 to
32.3°C); -4 to 140°F (-20 to 60°C).
Response Time: 15 s.
Electrical Connections: Removable screw terminal block.
Conduit Connection: Duct mount: 1/2˝ NPS; OSA: 1/2˝ (22.3 mm).
Drift: < 1% RH/year.
RH Sensor: Capacitance polymer.
Temperature Sensor: Types 1, 2, 3: Solid state band gap; Curves A, B, C:
Thermistor; Curves D, E: Platinum RTD DIN 385.
Enclosure: Duct mount: PBT; OSA: Polycarbonate.
Enclosure Rating: Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X
(IP66).
Display: Duct mount only, optional 2-line alpha numeric, 8 characters/line.
Display Resolution: RH: 0.1%; 0.1°F (0.1°C).
Weight: Duct mount: .616 lb (.3 kg); OSA: 1 lb (.45 kg).
Agency Approvals: CE.
SERIES RHP
V
I
D
E
O
O
N
L
I
N
E
6-25/32
[172.09]
5-1/8
[130.18]
4-17/32
[115.09]
2-15/64
[56.75]
3-1/8
[79.38]
4-17/32
[115.09]
Ø3/16
[4.76]
MOUNTING
HOLES
TYP 4 PLCS
3-1/8
[79.38]
1-13/64
[30.56]
55/64
[21.83]
Duct mount
OSA (outside air)Sintered lter version
2-1/4
[57.15]
55/64
[21.83]
6-25/32
[172.16]
3-45/64
[94.06]
2-41/64
[67.07]
5-1/8
[130.18]
223
Humidity/Temperature
Transmitters
AIR QUALITY
DWYER INSTRUMENTS, INC. | dwyer-inst.com
YEAR LIMITED
WARRANTY
MODEL CHART
Example RHP -2 D 1 A -LCD RHP-2D1A-LCD
Series RHP RH/passive temperature sensor transmitter
Accuracy 2
3
5
2% accuracy
3% accuracy
5% accuracy
Housing
Type
D
O
S
R
Duct mount with plastic hydrophobic lter
OSA (outside air)
OSA with sintered lter*
Radiation shield
RH Output 1
2
3
4-20 mA
0-10 V
0-5 VDC
Temperature
Sensor
0
1
2
3
A
B
C
D
E
F
None
4-20 mA
0-10 VDC
0-5 VDC
10K @ 25°C thermistor type III
10K @ 25°C thermistor type II
3K @ 25°C thermistor
100 Ω RTD DIN 385
1K Ω RTD DIN 385
20K Ω @ 25°C thermistor
Options LCD
NIST
LCD display
NIST traceable calibration certicate
*Use OSA with sintered lter models when purchasing Series RHRS radiation shield
separately.
ACCESSORIES
Model Description
A-RHP-FC
A-RHP-RT
Replacement plastic hydrophobic lter
Retrot tool for tting O-ring on RHP-D/M models for new lter
A-RHP-FC
AirQuality_2021.indb 223 7/15/20 12:18 PM

Summary of content (1 pages)