Installation Sheet

7302029-100 Rev. B
11
9
10
ADJUSTMENTS
a. Adjust water level. Water level
should be adjusted to level indicated
on tank by adjusting oat cup.
See Step 10 for water level adjustment
method.
b. If bowl fails to siphon, an adjustment
may be required with the lift chain.
Simply remove the bead chain from
the retainment clip (see Fig. 9A) and
take up slack on the chain, and
reinsert on lift rod. Make sure the chain
is not too taught.
TANK
LEVER
"S"
CLIP
FLUSH
VALVE
TOP
ARM
NIPPLE
Diagram 1
PARTS FOR WATER
CONNECTION
(SEE STEP 9)
CONE WASHER
VALVE
BODY
FLAPPER
THREADED
SHANK
SHANK
WASHER
COUPLING NUT
(HAND TIGHT ONLY)
FILL
VALVE
FLOAT
CUP
CRITICAL LEVEL
MARK ("C.L.")
MUST BE
1" ABOVE
OVERFLOW PIPE
REFILL
TUBE
ADJUSTABLE
HEIGHT
WATER LEVEL
ADJUSTMENT
ROD
LOCK NUT
Fig. 9A
Turn on water supply.
Submerge the FLOAT CUP
under the water for 30
seconds. Adjust the water to
desired level by turning WATER
LEVEL ADJUSTMENT ROD
and moving FLOAT CUP up or
down.
Make sure water supply is
off. Remove valve TOP by
lifting arm and rotating top
and arm 1/8 turn
counterclockwise, pressing
down slightly on cap.
IMPORTANT: Always
clear sand and rust from
system.
• While holding a
container over the
uncapped VALVE to
prevent splashing, turn
water supply on and off
a few times. Leave
water supply off.
Replace TOP by engaging
lugs and rotating 1/8 turn
clockwise. MAKE
CERTAIN TIP IS TURNED
TO THE LOCKED
POSITION. VALVE MAY
NOT TURN ON IF TOP IS
NOT FULLY TURNED TO
THE LOCKED POSITION.
For troubleshooting information please contact:
TROUBLESHOOTING
IF FILL VALVE SHUTS OFF BUT CONTINUES TO LEAK
SLOWLY, repeat Step 11.
IF FILL VALVE TURNS OFF AND ON DURING PERIODS
OF NON-USE, it is a signal you are wasting water
because:
• The end of the refill tube is inserted into overflow pipe,
below
water level in tank. Attach rell tube to overow pipe
using "S"
clip provided.
• The flush valve is leaking because it's worn, dirty or
misaligned
with tank ball or apper (replace with a new apper).
IF FILL VALVE WON'T TURN ON OR SHUT OFF or
REFILL OF TANK WATER IS SLOW after valve has
been in use for some time, Fluidmaster Model 242
Replacement Seal may be needed.
Go to our website at www.fluidmaster.com for more
solutions to toilet problems.
© 2001 Fluidmaster, Inc.
® Registered trademark of Fluidmaster, Inc.
Always use quality Fluidmaster repair parts when maintaining your Fluidmaster products.
Fluidmaster shall not be responsible or liable for any damages caused by products used
with Fluidmaster valves that were not manufactured by Fluidmaster, Inc.