Installation Sheet

- 1 -
INSTALLATION INSTRUCTIONS
SAVE FOR FUTURE USE
Product names listed herein are trademarks of AS America, Inc.
© AS America, Inc. 2017
7302031-100 Rev. C (6/17)
RECOMMENDED TOOLS AND MATERIALS
Most of the procedures require the use of common tools and materials, which are available from hardware and plumbing
supply stores. It is tessential that the tools and materials be on hand before work is begun.
Thank you for selecting DXV. To ensure this product is installed properly, please read these instructions carefully before you begin.
(Certain installations may require professional help.) Also be sure your installation conforms to local codes.
CAUTION: PRODUCT IS FRAGILE. TO AVOID BREAKAGE AND POSSIBLE INJURY HANDLE WITH CARE!
NOTE: Pictures may not exactly define contour of china and components.
!
Fitzgerald
®
1.28 gpf / 4.8 Lpf 2-Piece Toilet
Elongated with Seat - Model# D2205CA101
Round Front with Seat - Model# D2205DA101
GasketWax Ring
Regular Screwdriver
10'
Level Flexible Supply Tube
Closet Bolts
Putty Knife
Tape Measure
Hacksaw
SealantAdjustable Wrench
a. Close toilet supply valve and ush tank completely. Towel or sponge remaining water from tank and bowl.
b. Disconnect and remove supply line. NOTE: If replacing valve, first shut off main water supply!
c. Remove old mounting hardware, remove toilet and plug oor waste opening to prevent escaping sewer gases.
d. Remove closet bolts from ange and clean away old wax, putty, etc. from base area.
NOTE: Mounting surface must be clean and level before new toilet is installed!
IMPORTANT: Water supply on the wall is required at 3" (76 or 229 mm) from centerline of the toilet (see rough-in). First
suggested position is hidden behind the toilet. The geometry of the toilet gives space for this installation. The second
suggested position is next to the toilet. Between these two positions, the space for the supply between wall and toilet is
limited to 3-1/2" (89 mm). In this case, check your supply and hose dimensions.
1
2a
REMOVE OLD TOILET
ROUGHING-IN DIMENSIONS: NOTE: Distance from wall to closet flange centerline must be as listed below:
ALL INSTALLATION PROCEDURES MUST COMPLY IN STRICT ACCORDANCE WITH APPLICABLE LOCAL
PLUMBING AND BUILDING CODES
Model# D2205CA101
29-7/8"
(758 mm)
7-7/16"
(189 mm)
18-1/2"
(470 mm)
16-1/2"
(419 mm)
15-1/16"
(383 mm)
31-3/16"
(792 mm)
FINISHED
FLOOR
C/L OF SEAT POST
HOLES 5-1/2"
(140mm) CENTERS
SUPPLY
AS
REQUIRED
(position 1 or
position 2)
6"
(152 mm)
5-1/2"
(140 mm)
14"
(356 mm)
3"
(76 mm)
13-1/2"
(342 mm)
12-3/8"
(315 mm)
9"
(229 mm)
1"
(26 mm)
3-1/2"
(88 mm)
2-3/4"
(70 mm)
3-3/8"
(85 mm)
70 C
L
8-9/16"
(217 mm)
13-11/16"
(348 mm)
12"
(305 mm)

Summary of content (5 pages)