Product Manual

7
Dyna-Glo
10K Portable Heater
Control Graphics
Scale 1:1
Dyna-Glo
18K Portable Heater
Control Graphics
Scale 1:1
LIGHTING / OPERATING INSTRUCTIONS
FOR USE WITH HOSE(S) CONNECTED TO A
REMOTE CYLINDER, MAXIMUM SIZE 20 LBS:
• This Heater may be used in a Recreational Enclosure or
Temporary Construction Work Enclosure with a Remote
Rellable Propane Cylinder ONLY when the Cylinder is
Located Outdoors and the Heater is Used with GHP
Hose No. HAKITDG.
• GHP Hose No. HAKITDG includes a hand-tightening tank
connector, a fuel lter and a #600 hose connector tting.
WARNING: NEVER bring a rellable propane cylinder indoors.
A re or explosion can occur causing property damage, serious
injury or death!
• Inspect the hose before each use of the heater. If there is
excessive abrasion or wear, or the hose is cut, replace prior to
using the heater with Dyna-Glo HAKITDG.
• The propane cylinder must include a listed overlling protection
device as well as a collar to protect the cylinder valve.
• Heater must be in an upright position during operation.
• Connect propane as described on page 6.
• Open valve at LP-gas supply cylinder.
• Check all hose connections for leaks with soapy water at all threaded
connection points and at the LP-gas supply cylinder.
SEE WARNING! ON ATTACHED LABELS.
• Follow the instructions for lighting the Heater as dened in steps 1
through 8 above.
LIGHTING, OPERATION, AND
SHUTDOWN INSTRUCTIONS
Unvented Portable Type Heaters Must Not be Exposed to Flammable
Vapors or Liquids.
1. Make sure the control knob is in the OFF position.
2. Open the access door as needed and install the one pound cylinder(s)
as described on page 5.
Check for gas leaks by using a 50% soap-water solution at
the joint of the regulator and cylinder.
3. Depress and turn the control knob to the pilot position.
a. If fueled by a 1 lb. propane cylinder, hold for 30 seconds.
b. If fueled by a 20 lb. propane cylinder, hold for 4-5 minutes.
With the knob still depressed, rotate the knob between the OFF and
PILOT position activating the piezo igniter until the pilot ame ignites.
4. Continue holding the knob down in the PILOT position
for 30 seconds or until pilot ame holds.
5. Release the knob. The knob should return to the fully
extended position and the pilot should remain lit.
6. Turn on the burner by depressing the knob slightly and
gently turn the knob to the HI position.
7. Adjust heat output by turning the knob between HI and
LOW position.
8. To shut down the heater turn the knob clockwise to the OFF
position and remove the gas cylinder or close the propane
tank shut off valve and allow the heater to burn off the gas in
the hose, then turn the heater knob to the OFF position.
CAUTION
Do not try to adjust heating levels by using the propane tank shutoff valve.
After turning heater off the guard will remain hot. Allow the heater to cool
down before storing the heater.
Do not operate, store, connect or remove cylinder/hose connection near
ammable items or ignition sources.
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
Fig. 2a - Model 10K Lighting Control Panel
Fig. 2b - Model 18K Lighting Control Panel
WIND
DIRECTION
PILOT
POSITION
OFF
POSITION
KNOB
INDICATOR
MARK
PILOT
POSITION
HIGH
POSITION
LOW
POSITION
CONTROL
KNOB
PIKOT FLAME
PILOT AIR HOLE
Regulator
1 lb. DOT Approved Cylinder
Tank
Regulator
Fuel Filter &
Hose Kit #
HAKITDG
VALVE
ODS PILOT
ASSY
ORIFICE
REGULATOR
Fig. 3 - Lighting in Windy Areas
LIGHTING IN WINDY AREAS
1. Position the heater such that the Pilot is opposite the direction that
the wind is coming from. See gure 3
2. Position your body behind the heater such that your body blocks the
wind while you are following the instructions for lighting the unit.
OFF
LOW
LOW
HIGH
PILOT
PILOT HIGH
OFF
MEDIUM