Installation Guide

18
1
2
3
4
5
O
F
F
P
I
L
O
T
OPERATION
THERMOSTAT GAS CONTROL
1. STOP! Read the safety information on the previous page.
2. Turn off all electric power to the appliance.
3. Turn control knob clockwise to "OFF" position. (See Fig. 22b)
4. Wait (5) minutes to clear out any gas. Then smell for gas, including
near the oor. If you smell gas, STOP! Follow “B” in the safety
information above. If you don’t smell gas, go to the next step.
5. Turn knob counterclockwise to the "PILOT" position.
(See Fig. 23b) Depress control knob.
6. With control knob depressed, push down on the ignitor button
until the pilot lights. The pilot is visible, centered below the main
burner, behind the glass panel. (See Fig. 24 on page 19)
7. Keep control depressed for (30) seconds after pilot lights. Release
control knob.
Note: If pilot goes out repeat steps 3 through 7. Wait (1) minute
before attempting to light pilot again. If after several tries the pilot
still goes out, turn the gas control knob clockwise
to the "OFF" position and call your service technician or gas sup-
plier. If the control knob does not pop up when released, stop and
immediately and call your service technician or gas supplier.
8. Turn on all electric power to the appliance.
9. Turn control knob counter clockwise to desired setting.
Fig. 22b
LIGHTING INSTRUCTIONS
If the control knob does not pop up when released, stop and immediately and call your service
technician or gas supplier.
8. Turn on all electric power to the appliance.
9. Turn control knob counter clockwise to desired setting.
Fig. 24 - Pilot Flame Location
Burner Patterns (Manual Control)
LOW
MED
HIGH
OFF
LOW
HIGH
OFF
HIGH
OFF
LOW
MED
HIGH
OFF
Fig. 23b
1
2
3
4
5
O
F
F
P
I
L
O
T