Instructions / Assembly

12
F.) SPARK PLUG
CLEAN AND REGAP EVERY 600 HOURS
OPERATION OR REPLACE AS NEEDED.
(For KFA50DGD/80DGD/135DGD/180DGD Models Only)
- Remove upper shell (See page 10).
- Remove fan (See page 10).
- Remove ignitor wire from spark plug.
- Remove spark plug from nozzle adaptor using medium
phillips screwdriver.
- Clean and regap spark plug electrodes to 3.5mm gap.
- Reinstall spark plug to nozzle adaptor.
- Attach ignitor wire to spark plug.
- Reinstall fan and upper shell.
(For KFA220DGD Model Only)
- Remove upper shell (See page 10).
- Remove fan (See page 10).
- Remove ignitor wire from nozzle adaptor.
- Remove spark plug from nozzle adaptor using medium
phillips screwdriver.
- Clean and regap spark plug electrodes to 3.5mm gap.
(0.138”)
- Reinstall spark plug to nozzle adaptor.
- Attach ignitor wire to spark plug.
- Reinstall fan and upper shell.
G.) PHOTOCELL
CLEAN PHOTOCELL ANNUALLY OR AS
NEEDED.
- Remove upper shell (See page 10).
- Remove fan (See page 10).
- Remove photocell from its mounting.
Clean photocell lens with cotton swab.
TO REPLACE:
- Remove side cover screws using medium phillips
screwdriver.
- Disconnect switch wires from power switch and
remove side cover.
- Disconnect wires from circuit board and remove
photocell.
- Install new photocell and connect wires to circuit
board.
- Replace switch wires to power switch and side cover.
- Replace fan and upper shell.
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
Screw
Spark Plug
Ignitor Wire
Side Cover
Power
Switch
Screw
Switch
Wires
Photocell
Lens
Bracket
Install Photocell
• Incorrect • Correct
Spark Plug
GAP
Nozzle Adaptor
Figure 16. Spark Plug Regap
Figure 17. Spark Plug Regap
Figure 18. Photocell Replacement
GAP
3.5mm / 0.138”
Ignitor Wire
Screw
Spark Plug
Nozzle Adaptor
Spark Plug
GAP