Installation Instructions
The heater is designed and approved for use as a construction heater under ANS Z83.7 CSA 2.14. It is hard
to anticipate every use which may be made of this heater. CHECK WITH YOUR LOCAL FIRE SAFETY
AUTHORITY IF YOU HAVE QUESTIONS ABOUT APPLICATIONS.
DYNA-GLO PROPANE FORCED AIR CONSTRUCTION HEATERS
This is a direct-red forced air construction heater for either indoor construction or outdoor use. Its intended
use is primarily the temporary heating of buildings or structures under construction, alteration or repair. All the
products of combustion generated by the heater are forced through the heater and released into the area being
heated. This heater operates at approximately 98%+ combustion efciency but still produces a small amount
of carbon monoxide. Humans can tolerate small amounts of carbon monoxide for short periods. Carbon
monoxide can build up in a heated space and failure to provide adequate ventilation could result in poisoning
or death.
PROPANE CONSTRUCTION HEATER
3 4
Other standards govern the use of fuel gases and heat producing products in specic applications.
Your local authority can advise you about these.
IMPORTANT: READ THIS USER’S MANUAL CAREFULLY AND COMPLETELY BEFORE TRYING
TO OPERATE OR SERVICE THIS HEATER. IMPROPER USE OF THIS HEATER CAN CAUSE
SERIOUS INJURY OR DEATH FROM FIRE, EXPLOSION AND CARBON MONOXIDE POISONING.
SPECIFICATIONS
WARNING
: NOT FOR USE WITH DUCT WORK.
RMCFA40DGP/
DGP01
FA50Series FA60Series
RMCFA100DGD/
DGP/DGP01
LPFA125DGD/
RMCFA125DGP/
DGP01
LPFA125H/H01/
RMCFA125DGD
RMCFA150DGD
40,000BTU/hr
30,000BTU/hr
50,000BTU/hr
30,000BTU/hr
60,000BTU/hr
70,000BTU/hr
100,000BTU/hr
70,000BTU/hr
125,000BTU/hr
70,000BTU/hr
125,000BTU/hr
120,000BTU/hr
150,000BTU/hr
Propane Propane Propane Propane Propane Propane Propane
CylinderPressure CylinderPressure CylinderPressure CylinderPressure CylinderPressure CylinderPressure CylinderPressure
5psig 5psig 5psig 5psig 5psig 5psig 5psig
11"W.C 11"W.C 11"W.C 11"W.C 11"W.C 11"W.C 11"W.C
1.9lbs/hr0.86kg/hr
1.4lbs/hr0.63kg/hr
2.3lbs/hr1.04kg/hr
1.4lbs/hr0.63kg/hr
2.8lbs/hr1.27kg/hr
3.3lbs/hr1.5kg/hr
4.6lbs/hr2.09kg/hr
3.3lbs/hr1.5kg/hr
5.8lbs/hr2.63kg/hr
3.3lbs/hr1.5kg/hr
5.8lbs/hr2.63kg/hr
5.6lbs/hr2.54kg/hr
7.0lbs/hr3,18kg/hr
120V,60Hz,1Ø 120V,60Hz,1Ø 120V,60Hz,1Ø 120V,60Hz,1Ø 120V,60Hz,1Ø 120V,60Hz,1Ø 120V,60Hz,1Ø
Amperage Load 0.68amps 0.65amps 0.65amps 0.7amps 0.7amps 0.7amps 0.7amps
Fan
Unload
Load
3550rpm
3000rpm
3570rpm
3300rpm
3570rpm
3300rpm
3580rpm
3300rpm
3580rpm
3300rpm
3580rpm
3300rpm
3580rpm
3300rpm
Piezo/ManualSpark ContinuousSpark ContinuousSpark ContinuousSpark ContinuousSpark ContinuousSpark ContinuousSpark
0.16"(4mm) 0.16"(4mm) 0.16"(4mm) 0.16"(4mm) 0.16"(4mm) 0.16"(4mm) 0.11"(2.8mm)
19.3"x8.3"x15.2"
(49.0x21.1x38.6)cm
19.3"x8.3"x15.2"
(49.0x21.1x38.6)cm
19.3"x8.3"x15.2"
(49.0x21.1x38.6)cm
25.6"x12.7"x15.6"
(65.0x32.3x39.6)cm
25.6"x11.8"x16.1"
(65.0x30.0x40.9)cm
26.6"x13.0"x17.3"
(67.6x33.0x43.9)cm
25.6"x11.8"x16.1"
(65.0x30.0x40.9)cm
26.2"x11.8"x17.2"
(66.6x30.0x43.6)cm
25.6"x11.8"x16.1"
(65.0x30.0x41.0)cm
25.6"x11.8"x16.1"
(65.0x30.0x40.9)cm
Size(LxWxH)
ManifoldPressure
GasConsumption
ElectricalInput
Ignition
SparkGap
ModelNo.
InputRating
TypeofGas
GasSupplyPressureto
RegulatorMaximum
Minimum(forpurposeof
InputAdjustment)
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!