Pill Reminder Device User Manual

ITW Dynatec c. 1999 Page 2 - 7
TPC-2 TIMER Manual #50-05 Revised 11/04
230VAC Power Cord Wiring
WIRE COLOR DESIGNATION
Brown or Black Power (+)
Blue or White Neutral (-)
Green Ground
CAUTION: Avoid the installation of input or output cords near or parallel to
power lines from other machinery. The resulting electrical “noise” can produce
adverse effects on the TPC-2 Control Unit which could result in unreliable
operation.
Receptacle Assignments
Below are the pin assignments for the input/output receptacles located at the bottom of
the TPC-2 Control Unit.
P
IN ASSIGNMENT
RECEPTACLE
1 2 3 4 5 6 7 8 9
DRIVE 1
-
minus
+16V
DC
DRIVE 2
-
minus
+16V
DC
A.T.S.
-
minus
+16V
DC
TRIGGER
+12V
DC
Gnd
Signal
(NPN)
Chas-
sis
Gnd
NOTE: shorting pins #2 & #3 will
manually initiate the trigger.
PURGE
-
minus
+12V
DC
cont.
Drive 1 Drive 2 Tri
gg
er
TS Pur
g
e
123
456
789
1
23
4