Pill Reminder Device User Manual

ITW Dynatec c. 1999 Page 3 - 5
TPC-2 TIMER Manual #50-05 Revised 1/99
PURGE Display Settings
DISPLAY MEANING
= = = 0
Activation of A.T.S. output only
= = = 1
Activation of A.T.S. and DRIVE 1 outputs
= = = 2
Activation of A.T.S. and DRIVE 2 outputs
3. Activation of the selected outputs occurs upon depressing the button on the Purge
Control Unit (106078) and continues until the button is released.
Trig Mode
The TRIG MODE (Trigger Mode) parameter allows the Operator to select the manner in
which the TPC-2 Control Unit applies the programmed pattern upon receiving a trigger
(i.e. photo sensor, footswitch, etc.) input.
1. Depress the SYSTEM button until the yellow LED to the left of TRIG MODE is
illuminated.
2. Rotate the VALUE knob until the desired TRIG MODE setting is selected. The table
below indicates the meaning of each display setting.
TRIG MODE Display Settings
DISPLAY MEANING
GAt.
Gated Repeat – the trigger signal initiates the glue cycle, which repeats continuously until the trigger
signal ends. The glue cycle stops immediately upon loss of trigger signal
, regardless of the state of
the glue cycle.
LAt.
Latched Repeat - the trigger signal initiates the glue cycle, which repeats continuously until the
trigger signal ends. The glue cycle stops upon completion of the pattern cycle after loss of trigger
signal.
GAt.-
Gated Single – the trigger signal initiates the glue cycle, a single glue pattern is performed. The glue
cycle stops immediately if the trigger signal is lost during the cycle
, regardless of the state of the glue
cycle.
LAt.-
Latched Single - the trigger signal initiates the glue cycle, a single glue pattern is performed. The
glue cycle stops upon completion of the pattern cycle
.
Time Range
The TPC-2 offers two time ranges for programming of DELAY and LINE settings: 0.001
(i.e. 1ms) to 1.999 seconds and 0.01 (i.e. 10ms) to 19.99 seconds.
1. Depress the SYSTEM button until the yellow LED to the left of TIME RANGE is
illuminated.
2. Rotate the VALUE knob until the desired TIME RANGE setting is selected. The table
below indicates the meaning of each display setting.