Pill Reminder Device User Manual

ITW Dynatec c. 1999 Page 4 - 3
TPC-2 TIMER Manual #50-05 Revised 1/99
11. Use the same procedure as in Steps #6 through #9 above until 0090 (or 90ms) is
displayed.
12. Depress the CHANNEL 1 button until the LED to the left of GAP is illuminated.
13. Use the DIGIT button and VALUE knob to set the display to 0010 (or 10ms).
NOTE: Once a value is selected in GAP the LINE length is divided by the gap figure.
The output from the TPC-2 Control Unit will be dots (i.e. the Glue Applicator is fired 9
times at 10ms intervals for the duration of SPIKE TIME for each cycle).
14. Depress the CHANNEL 1 button until the LED to the left of STITCH is illuminated.
The value of this parameter should read 0000 since dots are desired.
15. Depress the CHANNEL 1 button until the LED to the left of SPIKE TIME is
illuminated.
16. Use the DIGIT button and VALUE knob to set the appropriate SPIKE TIME for the
Glue Applicator (approximately 2ms, 002.0).
17. Depress the RUN/STOP button until the LED above this button is illuminated. The
glue system is now ready for operation.
At this point some product should be run. Examine the finished product to assure the
TPC-2 Control Unit’s time settings suit the line speed of the machine. If incorrect, follow
the above procedure and change values where necessary.
A Multiple EVENT Glue Pattern
The following example places a series of dots, dashes and a solid line on a substrate using
two glue applicators.