Pill Reminder Device User Manual

ITW Dynatec c. 1999 Page 4 - 5
TPC-2 TIMER Manual #50-05 Revised 1/99
9. Rotate the VALUE knob until the second digit from the left is an 8. The display should
now read 0080 (or 80ms).
10. Depress the CHANNEL 1 button until the LED to the left of LINE is illuminated.
11. Use the same procedure as in Steps #6 and #7 above until 0060 (or 60ms) is
displayed.
12. Depress the CHANNEL 1 button until the LED to the left of GAP is illuminated.
13. Use the DIGIT button and VALUE knob to set the display to 0010 (or 10ms).
NOTE: Once a value is selected in GAP the LINE length is divided by the GAP figure.
The output from the TPC-2 Control Unit will be dots (i.e. the Glue Applicator is fired 6
times at 10ms intervals for the duration of SPIKE TIME for each cycle).
14. Depress the CHANNEL 1 button until the LED to the left of STITCH is illuminated.
The value of this parameter should read 0000 since dots are desired.
15. Depress the CHANNEL 1 button until the LED to the left of SPIKE TIME is
illuminated.
16. Use the DIGIT button and VALUE knob to set the appropriate SPIKE TIME for the
Glue Applicator (approximately 2ms, 002.0).
17. Depress the CHANNEL 1 button until the LED to the left of EVENT is illuminated.
18. Rotate the VALUE knob until 2 is displayed. This indicates the programming of
EVENT 2 of the selected Program. EVENT 2 is the series of STITCHED glue lines.
19. Depress the CHANNEL 1 button until the LED to the left of DELAY is illuminated.
20. Use the DIGIT button and VALUE Knob to set the display to 0160 (160ms, the sum
of DELAY1, LINE1, and DELAY2).
21. Depress the CHANNEL 1 button until the LED to the left of LINE is illuminated.
22. Use the DIGIT button and VALUE Knob to set the display to 0060 (60ms).
23. Depress the CHANNEL 1 button until the LED to the left of GAP is illuminated.
24. Use the DIGIT button and VALUE knob to set the display to 0010 (or 10ms). This
represents the “no glue” duration of the STITCH within a LINE.
25. Depress the CHANNEL 1 button until the LED to the left of STITCH is illuminated.
26. Use the DIGIT button and VALUE knob to set the display to 0010 (or 10ms). This
represents the duration of the “glue” portion of the STITCH pattern with a LINE.