Pill Reminder Device User Manual

Page 4 - 6 ITW Dynatec c. 1999
Revised 1/99 TPC-2 TIMER Manual #50-05
NOTE: The SPIKE TIME parameter is not accessible when programming EVENT2
through EVENT4. Programming of SPIKE TIME for each CHANNEL occurs only
during EVENT1.
27. Depress the CHANNEL 1 button until the LED to the left of EVENT is illuminated.
28. Rotate the VALUE knob until 3 is displayed. This indicates the programming of
EVENT 3 of the selected Program. EVENT 3 is a solid glue line.
29. Depress the CHANNEL 1 button until the LED to the left of DELAY is illuminated.
30. Use the DIGIT button and VALUE Knob to set the display to 0240 (240ms, the sum
of DELAY1, LINE1, DELAY2, LINE2 and DELAY3).
31. Depress the CHANNEL 1 button until the LED to the left of LINE is illuminated.
32. Use the DIGIT button and VALUE Knob to set the display to 0060 (60ms).
33. Depress the CHANNEL 1 button until the LED to the left of GAP is illuminated.
34. Use the DIGIT button and VALUE knob to set the display to 0000 (or 0ms). EVENT3
is a solid line, so no GAP is required.
35. Depress the CHANNEL 1 button until the LED to the left of STITCH is illuminated.
36. Use the DIGIT button and VALUE knob to set the display to 0000 (or 0ms). EVENT3
is a solid line, so no STITCH is required.
37. Repeat Step #5 through Step #36 above for CHANNEL 2.
38. Depress the RUN/STOP button until the LED above this button is illuminated. The
glue system is now ready for operation.
At this point some product should be run. Examine the finished product to assure the
TPC-2 Control Unit’s time settings suit the line speed of the machine. If incorrect, follow
the above procedure and change values where necessary.