Pill Reminder Device User Manual

Page 1 - 2 ITW Dynatec c. 1999
Revised 1/99 TPC-2 TIMER Manual #50-05
The TPC-2 possesses a PALLETISING facility that provides an easy means of applying
glue to a specified number of objects, then passing (or skipping) a specified number of
objects. The display continually updates itself to inform the operator of the current
COUNT.
A key-actuated system lock is provided on the Controller’s front panel. This lock prevents
any unauthorized change to the programming when activated.
Specifications
Operating Temperature: 32 to 113 degrees F (0 to 45 degrees C), 0 to 90% RH, non-condensing
Storage Temperature: -14 to 140 degrees F (-10 to 60 degees C), 0 to 90% RH, non-condensing
Maximum Switching Rate: 500 cycles per second
Maximum Power Output: 26 Watts, current limited at 1.25 amps per channel
Applicator Overload Protection: Electronic Sensing
Time Increments: 0.001 to 1.999 seconds or 0.01 to 19.99 seconds (operator selectable)
Holding Voltage: 16 VDC
Over-Voltage: 48 VDC
Over-Voltage Duration: 0 to 25.5ms, operator selectable
Input Voltage:
115 or 230 VAC ± 10% (requires installation of appropriate jumper), single
phase
Input Power: 60 Watts
How to Use this Manual
The following typographic conventions are used throughout this manual:
ALL CAPITALS: Parameter, Button and Knob titles displayed on the TPC-2 Control
Unit Display Panel
Bold: Information found on the TPC-2 Control Unit’s LED Display