PSI 5000 A Series
320 W
Model
PSI 5040-20 A PSI 5080-10 A PSI 5200-04 A
AC Input
Input voltage 90...264 V AC 90...264 V AC 90...264 V AC
Input connection 1ph,N,PE 1ph,N,PE 1ph,N,PE
Input frequency 50/60 Hz 50/60 Hz 50/60 Hz
Input fuse (internal) MT 4 A MT 4 A MT 4 A
Leak current < 3.5 mA < 3.5 mA < 3.5 mA
Power factor ~ 0.99 ~ 0.99 ~ 0.99
DC Output
Max. output voltage U
Max
40 V 80 V 200 V
Max. output current I
Max
20 A 10 A 4 A
Max. output power P
Max
320 W 320 W 320 W
Overvoltage protection range 0...44 V 0...88 V 0...220 V
Overcurrent protection range 0...22 A 0...11 A 0...4.4 A
Overpower protection range 0…352 W 0…352 W 0…352 W
TemperaturecoefcientforsetvaluesΔ/K Voltage / current: 100 ppm
Voltage regulation
Adjustment range 0...40.8 V 0...81.6 V 0...204 V
Accuracy
(1
(at 23 ± 5°C) < 0.1% U
Nom
< 0.1% U
Nom
< 0.1% U
Nom
Lineregulationat±10%ΔU
AC
< 0.02% U
Nom
< 0.02% U
Nom
< 0.02% U
Nom
Load regulation at 0...100% load < 0.05% U
Nom
< 0.05% U
Nom
< 0.05% U
Nom
Risetime10...90%ΔU Max. 30 ms Max. 30 ms Max. 30 ms
Display: Resolution See section „1.9.4.3. Resolution of the displayed values“
Display: Accuracy
(4
≤0.2%U
Nom
≤0.2%U
Nom
≤0.2%U
Nom
Ripple
(2
< 40 mV
PP
< 5 mV
RMS
< 80 mV
PP
< 10 mV
RMS
< 150 mV
PP
< 30 mV
RMS
Remote sensing compensation Max. 6% U
Nom
Max. 6% U
Nom
Max. 6% U
Nom
Current regulation
Adjustment range 0...20.4 A 0...10.2 A 0...4.08 A
Accuracy
(1
(at 23 ± 5°C) < 0.2% I
Nom
< 0.2% I
Nom
< 0.2% I
Nom
Lineregulationat±10%ΔU
AC
< 0.05% I
Nom
< 0.05% I
Nom
< 0.05% I
Nom
Load regulation at 0...100% load < 0.15% I
Nom
< 0.15% I
Nom
< 0.15% I
Nom
Ripple
(2
< 80 mA
PP
< 40 mA
PP
< 16 mA
PP
Display: Resolution See section „1.9.4.3. Resolution of the displayed values“
Display: Accuracy
(4
≤0.2%I
Nom
≤0.2%I
Nom
≤0.2%I
Nom
Compensation 10%->90% load < 1.5 ms < 1.5 ms < 1.5 ms
Power regulation
Adjustment range 0…320 W 0…320 W 0…320 W
Accuracy
(1
(at 23 ± 5°C) < 1% P
Nom
< 1% P
Nom
< 1% P
Nom
Lineregulationat±10%ΔU
AC
< 0.05% P
Nom
< 0.05% P
Nom
< 0.05% P
Nom
Loadregulationat10-90%ΔU
OUT
*ΔI
OUT
< 0.75% P
Nom
< 0.75% P
Nom
< 0.75% P
Nom
Display: Resolution See section „1.9.4.3. Resolution of the displayed values“
Efciency
(3
~ 93% ~ 93% ~ 93%
(1Relatedtothenominalvalues,theaccuracydenesthemaximumdeviationbetweenanadjustedvaluesandthetrue(actual)value.
Example: a 80 V model has min. 0.1% voltage accuracy, that is 80 mV. When adjusting the voltage to 5 V, the actual value is allowed to differ max. 80 mV, which
means it might be between 4.92 V and 5.08 V.
(2 RMS value: LF 0...300 kHz, PP value: HF 0...20MHz
(3 Typical value at 100% output voltage and 100% power
(4 The display error (reciprocal of accuracy) adds to the general error of a value, so the total error will be higher.