2. Installation & commissioning
2.1 Storage
2.1.1 Packaging
It is recommended to keep the complete transport packaging for the lifetime of the device for relocation or return
to the manufacturer for repair. Otherwise the packaging should be disposed of in an environmentally friendly way.
2.1.2 Storage
In case of long term storage of the equipment it is recommended to use the original packaging or similar. Storage
must be in dry rooms, if possible in sealed packaging, to avoid corrosion, especially internal, through humidity.
2.2 Unpacking and visual check
After every transport, with or without packaging, or before commissioning, the equipment should be visually
inspected for damage and completeness using the delivery note and/or parts list (see section „1.9.2. Scope of
delivery“). An obviously damaged device (e.g. loose parts inside, damage outside) must under no circumstances
be put in operation.
2.3 Installation
2.3.1 Preparation
Mains connection for a PSI 5000 A series device is done via the included 1.5 meters long 3 pole mains cord. It is
required to operate the device with this or a similar cord which features a ground conductor. The ground is important
for safety and radio interference suppression.
When extending the power cord with extension cable(s) or power strip(s), it is important not to interrupt the ground
connection.
2.3.2 Installing the device
• Select the location for the device so that the connection to the load is as short as possible.
• Leavesufcientspacebehindtheequipment,minimum30cm,forventilation.
The device supposed to be operated in horizontal position. However, installing it in racks or cabinets is possible if
protective measure are not made invalid or are interrupted and ventilation slots are not impeded.
Acceptable and inacceptable installation positions:
Standing surface