User manual

Page 34
PSI 5000 A Series
www.elektroautomatik.de
ea1974@elektroautomatik.de
EA Elektro-Automatik GmbH
Helmholtzstr. 31-33 • 41747 Viersen
Germany
Fon: +49 2162 / 3785-0
Fax: +49 2162 / 16230
3.5.4.3 Analog interface specication
Pin Name Type* Description Levels Electrical properties
1 VSEL AI Set voltage value
0…10 V or. 0...5 V corre-
spond to 0..100% of U
Nom
Accuracy < 0.2% ****
Input impedance R
i
>40 k...100 k
2 CSEL AI Set current value
0…10 V or. 0...5 V corre-
spond to 0..100% of I
Nom
3 VREF AO Reference voltage 10 V or 5 V
Tolerance < 0.2% at I
max
= +5 mA
Short-circuit-proof against AGND
4 DGND POT
Ground for all
digital signals
For control and status signals.
5 REMOTE DI
Switching internal /
remote control
Remote = LOW, U
Low
<1 V
Internal = HIGH, U
High
>4 V
Internal = Open
Voltage range = 0…30 V
I
Max
= -1 mA bei 5 V
U
LOW to HIGH typ.
= 3 V
Rec’d sender: Open collector against DGND
6 OT DO
Overheating or
power fail*** alarm
Alarm OT= HIGH, U
High
> 4 V
No Alarm OT= LOW, U
Low
<1
V
Quasi open collector with pull-up against Vcc **
With5Vonthepinmax.currentow+1mA
I
Max
= -10 mA at U
CE
= 0,3 V
U
Max
= 30 V
Short-circuit-proof against DGND
7 - - - - -
8 PSEL AI Set power value
0…10 V or. 0...5 V corre-
spond to 0..100% von P
Nom
Accuracy < 0.2% ****
Input impedance R
i
>40 k...100 k
9 VMON AO Actual voltage
0…10 V or. 0...5 V corre-
spond to 0..100% von U
Nom
Accuracy < 0.2% at I
Max
= +2 mA
Short-circuit-proof against AGND
10 CMON AO Actual current
0…10 V or. 0...5 V corre-
spond to 0..100% von I
Nom
11 AGND POT
Ground for all
analog signals
For -SEL, -MON, VREF Signals
12 - - - - -
13 REM-SB DI
DC output OFF
(DC output ON)
(ACKalarms)
Off = LOW, U
Low
<1 V
On= HIGH, U
High
>4 V
On = Open
Voltage range = 0…30 V
I
Max
= +1 mA at 5 V
Rec’d sender: Open collector against DGND
14 OVP DO Overvoltage alarm
Alarm OV = HIGH, U
High
> 4 V
No alarm OV = LOW, U
Low
<1 V
Quasi open collector with pull-up against Vcc **
With5Vonthepinmax.currentow+1mA
I
Max
= -10 mA at U
CE
= 0,3 V, U
Max
= 30 V
Short-circuit-proof against DGND
15 CV DO
Constant voltage
regulation active
CV = LOW, U
Low
<1 V
CC/CP = HIGH, U
High
>4 V
* AI = Analog Input, AO = Analog Output, DI = Digital Input, DO = Digital Output, POT = Potential
** Internal Vcc approx. 14.3 V
*** Mains blackout, mains over- or undervoltage or PFC error
***** The error of a set value input adds to the general error of the related value on the DC output of the device
3.5.4.4 Overview of the Sub-D Socket