1.8.3 Specic technical data
(1Relatedtothenominalvalues,theaccuracydenesthemaximumdeviationbetweenanadjustedvaluesandthetrue(actual)value.
Example: a 80 V model has min. 0.1% voltage accuracy, that is 80 mV. When adjusting the voltage to 5 V, the actual value is allowed to differ max. 80 mV, which
means it might be between 4.92 V and 5.08 V.
(2 RMS value: LF 0...300 kHz, PP value: HF 0...20MHz
(3 The display error adds to the error of the related actual value on the DC output
320 W
Model
PSI 9040-20 DT PSI 9080-10 DT PSI 9200-04 DT
AC Input
Voltage range 90...264 V AC 90...264 V AC 90...264 V AC
Connection 1ph,N,PE 1ph,N,PE 1ph,N,PE
Frequency 45-65 Hz 45-65 Hz 45-65 Hz
Fusing MT 8 A MT 8 A MT 8 A
Leak current < 3.5 mA < 3.5 mA < 3.5 mA
Power factor ~ 0.99 ~ 0.99 ~ 0.99
DC Output
Max. output voltage U
Max
40 V 80 V 200 V
Max. output current I
Max
20 A 10 A 4 A
Max. output power P
Max
320 W 320 W 320 W
Overvoltage protection range 0...44 V 0...88 V 0...220 V
Overcurrent protection range 0...22 A 0...11 A 0...4.4 A
Overpower protection range 0…352 W 0…352 W 0…352 W
Output capacitance 4760μF 3400μF 720μF
Temperaturecoefcientforset
valuesΔ/K
Voltage / current: 100 ppm
Voltage regulation
Adjustment range 0...40 V 0...80 V 0...200 V
Accuracy
(1
(at 23 ± 5°C) < 0.1% U
Max
< 0.1% U
Max
< 0.1% U
Max
Lineregulationat±10%ΔU
AC
< 0.02% U
Max
< 0.02% U
Max
< 0.02% U
Max
Load regulation at 0...100% load < 0.05% U
Max
< 0.05% U
Max
< 0.05% U
Max
Rise time 0...100% (@full load) Max. 30 ms Max. 60 ms Max. 65 ms
Settling time after load step < 1.5 ms < 1.5 ms < 1.5 ms
Display: Resolution See section „1.9.5.4. Resolution of the displayed values“
Display: Accuracy
(3
≤0.2%U
Max
≤0.2%U
Max
≤0.2%U
Max
Ripple
(2
< 8 mV
PP
< 0.8 mV
RMS
< 8 mV
PP
< 0.8 mV
RMS
< 20 mV
PP
< 2.5 mV
RMS
Remote sensing compensation Max. 5% U
Max
Max. 5% U
Max
Max. 5% U
Max
Output voltage fall time (at no load)
after switching DC output off
- Down from 100% to <60 V: less than 10 s
Current regulation
Adjustment range 0...20 A 0...10 A 0...4 A
Accuracy
(1
(at 23 ± 5°C) < 0.2% I
Max
< 0.2% I
Max
< 0.2% I
Max
Lineregulationat±10%ΔU
AC
< 0.05% I
Max
< 0.05% I
Max
< 0.05% I
Max
Loadregulationat0...100%ΔU
OUT
< 0.15% I
Max
< 0.15% I
Max
< 0.15% I
Max
Ripple
(2
< 1 mA
RMS
< 1 mA
RMS
< 1,5 mA
RMS
Display: Resolution See section „1.9.5.4. Resolution of the displayed values“
Display: Accuracy
(3
≤0.2%I
Max
≤0.2%I
Max
≤0.2%I
Max
Power regulation
Adjustment range 0…320 W 0…320 W 0…320 W
Accuracy
(1
(at 23 ± 5°C) < 1% P
Max
< 1% P
Max
< 1% P
Max
Lineregulationat±10%ΔU
AC
< 0.05% P
Max
< 0.05% P
Max
< 0.05% P
Max
Loadreg.at10-90%ΔU
OUT
*ΔI
OUT
< 0.75% P
Max
< 0.75% P
Max
< 0.75% P
Max