User manual

29
© 2009, Elektro-Automatik GmbH & Co. KG
EN
Functional description
Notes:
Names in brackets () are related to functions in Power
Supply mode only.
• The number behind a setting, eg. „/7“, indicates the
corresponding pin of the 12 pole analogue terminal.
Explanations:
Menu item Parameter Meaning
General settings
Use of device Charger Device will work as charger
Power Supply
Device will work as power supply
Power ON restore
Output condition will be restored
after mains return
OFF
Output will always be off after
mains return
Backlight delay 60s
Display backlight will switch off
after a delay of 60s. Switches on
with every buttonpress
ON Backlight permanently on
Analogue interface
Temp.sensor /1 NO
Temperature sensor is not used
LM335A
Type LM335A is used
KTY81-210 KTY81-210 is used
Remote /7 LOW Remote control at pin = low
HIGH Remote control at pin = high
Charge(Rem-SB) /8
LOW Start charging at pin = low
HIGH Start charging at pin = high
Bat.full /2 LOW Pin signalises „Battery full“ = low
HIGH Pin signalises „Battery full“ = high
Charging /3
LOW Pin signalises „Charging...“ = low
HIGH Pin signalises „Charging...“ = high
ERROR /9 LOW Pin signalises „Error“ = low
HIGH Pin signalises „Error“ = high
CV /11 LOW Pin signalises low = CV, high = CC
HIGH Pin signalises low = CC, high = CV
Communication
Device node 1...30 Device node, device address
IP 0...255 Device IP (only IF-E2)
GW 0...255 Gateway (only IF-E2)
SNM 0...255 Subnet mask (only IF-E2)
RS232
div. Baud rate setting at IF-R2
Baudrate div. Baud rate setting at IF-C2
relocate ID seg 0...31
Select address segment for CAN
ID (only IF-C2)
Bus termination YES Bus termination on (only IF-C2)
NO Bus termination off (only IF-C2)
Options
Reset conguration
All settings are restored to default,
including the battery prole, if YES
is selected and submitted
Lock setup
Locks the settings in the setup
menu with a 4 digit PIN
Unlock setup
Unlock setup by entering PIN
again
About
Displays device type and manufacturer
Important notes about the settings:
„Remote /7“ and „RUN (Rem-SB) /8“ should remain
set to LOW if the analogue interface is not used,
because they are high by default
Setting „Power ON = OFF“ will result in the device
not continue charging or switching output on after a
mains blackout
Menu: „Battery prole selection“
All proles are modiable, but the battery type is assi-
gned like this:
Proles 1 - 6: Lead batteries, various types
Proles 7-10: Lithium batteries, various types
Proles 11-12: Nickel batteries, various types
Overview:
Actions:
1. Select battery prole for use
+ +
2. Modify battery prole
+ +
3. Navigate in the battery prole
+ + +
4. Change value(s) in the battey prole
+ + + +
then change with . When nished, submit
with or abort with .