User manual

30
© 2006, Elektro-Automatik GmbH & Co. KG
Irrtümer und Änderungen vorbehalten
EN
© 2009, Elektro-Automatik GmbH & Co. KG
Functional description
The battery proles
The selected battery prole should be modied by
the user to t the requirements of the battery! The
charging current is very important here.
The proles items are almost identical. They only differ
in some battery-specic parameters. All adjustable va-
lues are related to the charging characteristics and the
corresponding battery type. Also see section „Charging
procedures“.
Important: the proles are seperated into two sub-
proles:
A) The main battery parameters. Accessible via the
button and then :
1. Line Prole number, battery type, name (
maximum 10 characters)
Bat. U nom Battery nominal voltage (at Pb)
(not adjustable)
Cell U nom Cell voltage (at Ni/Li)
(Range: 2.000V...6.000V)
U charge Normal charge voltage of battery
/ cell (at Pb)
(Range: 2.000V...6.000V)
Cell U charge Normal charge voltage of cell (Ni/Li)
(Range: 2.000V...6.000V)
Cells Number of cells per battery
(Range: 1...99s )
1
I charge Charging current (in C)
(Range: 0.01...10.0C
Capacity Battery capacity
(
Range
: 1.000Ah...3.200kAh)
1 The „s“ indicates that the cells are connected in series
Note: the charging current I charge is adjusted in C.
This value is directly depending on the adjusted battery
capacity. It applies: if, for example, a battery capacity
of 120Ah is given, then 1C = 120A. The recommended
charging current is mostly given by the battery manuf-
acturer in the datasheet and should be used here.
B) The subparameters like temperatures, cell voltage,
or charging currents for the different charging phases.
Accessible via the button :
<- Li/Ni
<- Pb
The additional seperation is used to gain clarity and
divides the subparameters by afliation.
For the three supported battery types, different para-
meters result. See the next the pages.