Operating instructions

As the colours of the wires in the mains lead of the application
may not correspond with the coloured markings identifying the
terminals in your plug, proceed as follows:
The wire which is coloured blue must be connected to the
terminal which is marked with the letter N or coloured black.
The wire which is coloured brown must be connected
to the terminal which is marked with the letter L or
coloured red.
If you need to fit a plug to the mains cord, this should be fitted in accordance with the wiring
instructions below, and will need to be used with a 5 Amp fuse approved to BS 1362. If in doubt
consult a qualified electrician.
If you are using an extension lead it must be rated at a minimum of 6 Amps and fully unwound.
Do not operate with a lead rated less than 6 Amps as this will cause premature failure of the
motor which is not covered by the guarantee.
13
Screw the Fluid Tip (4) in place. Gently tighten with a spanner.
Insert Fluid Needle (6) into the back of the gun.
Next place the Spring (7) into the back of the gun over the Fluid Needle (6).
Hold the Trigger (14) down whilst you screw the Fluid Adjusting Screw (8) into place.
Release Trigger (14).
Place the Spray Direction Plate (3) on top of the Fluid Tip (4).
Place the Air Cap (2) over the Fluid Tip (4).
Screw on the Air Cap Ring (1).
Tighten the Gland Nut (9).
1.
2.
3.
4.
5.
7.
6.
8.
N
eed
le Assem
b
ly
Mains Co
nnectio
n
This unit is a Class II appliance which means it is double-insulated for your protection, no
earthing wire is necessary.
If the supply cord is damaged, it must be replaced by Earlex Ltd or our appointed agents to avoid
a hazard.
Your unit has been supplied with a mains cord fitted with a fuse plug. This is identified by the
fuse holder in the base of the plug. Please read the following safety instructions before use.
If the fitted plug is cut off from the mains cord then the plug must be disposed of safely.
NEVER under any circumstances insert such a plug into a 13 Amp socket-outlet.
NEVER under any circumstances use the appliance or mains cord without the fuse cover
fitted. This is the little cover fixed into the base of the plug to hold the fuse in place.
If you lose the fuse cover then please contact any electrical dealer for a replacement or ring
our helpline.
A replacement fuse must be rated at 5 Amps. This must be manufactured and approved to
BS 1362.
IF IN ANY DOUBT CONTACT A QUALIFIED ELECTRICIAN.
1.
2.
3.
4.
5.