TROUBLESHOOTING GUIDE
PROBLEM POSSIBLE CAUSE REMEDY/ACTION
Engine will not start 1. Ignition switch o 1. Flip switch to ON position
2. Spark plug wire disconnected 2. Connect spark plug wire to spark plug
3. Out of fuel 3. Refuel
4. Spark plug wet, faulty or improperly
gapped
4. Clean, replace or gap spark plug
5. Stale fuel 5. Drain old fuel and replace with fresh. Use fuel
stabilizer at end of season or during long term
storage
Engine runs rough, oods
during operation
1. Dirty air lter 1. Clean or replace air lter
2. Carburetor out of adjustment 2. Contact your engine manufacturer (Kohler, Briggs
& Stratton, Honda)
Engine is hard to start 1. Stale fuel 1. Drain old fuel and replace with fresh fuel. Use fuel
stabilizer at end of season or during long term
storage
2. Spark plug wire loose 2. Make sure spark wire is securely attached to spark
plug
3. Dirty carburetor 3. Clean carburetor, use fuel stabilizer, new gas can
Engine misses or lacks
power
1. Clogged fuel lter 1. Clean fuel tank, replace fuel lter
2. Clogged air lter 2. Clean or replace air lter
3. Carburetor out of adjustment or bad 3. Contact your engine manufacturer (Kohler, Briggs
& Stratton, Honda)
4. Spark plug wet, faulty or improperly
gapped
4. Clean, replace or gap spark plug
Engine runs, then quits 1. Clogged fuel lter 1. Clean fuel tank, replace fuel lter
2. Carburetor out of adjustment or bad 2. Contact your engine manufacturer (Kohler, Briggs
& Stratton, Honda)
Engine revs too high 1. Carburetor out of adjustment or bad 1. Contact your engine manufacturer (Kohler, Briggs
& Stratton, Honda)
Auger turn at idle 1. Idle speed too high 1. Adjust idle speed lower
2. Broken clutch spring 2. Replace clutch
Auger turns, but has no
power
1. Carburetor out of adjustment or bad 1. Contact your engine manufacturer (Kohler, Briggs
& Stratton, Honda)
2. Broken transmission 2. Replace transmission
3. Worn clutch shoes 3. Replace clutch
Auger jumps 1. Blade damaged 1. Replace with new blade
Auger cuts slowly 1. Dull blade 1. Replace with new blade
2. Damaged shtail point 2. Replace shtail point
3. Blade installed upside down 3. Install blade right side up (bevel side down)
Note: Please refer to your Engine Manual for any additional engine issues.
Kohler | www.KohlerEngines.com | (800) 544-2444
Briggs & Stratton | www.BriggsandStratton | (800) 444-7774
Honda | www.engines.Honda.com | (800) 242-2289
12
Operator's Manual
Two-Man Earth Auger Powerhead 9800 Series
Check for parts online at www.getearthquake.com or call 800-345-6007 M-F 8-5