Product Brochure

Premium residential products
Eaton has enhanced its premium Type CH residential circuit
breakers, making the best even better. The Type CHF AFCI
breakers also include advanced electronics that reduce nuisance
tripping and a standard diagnostic LED indicating one of seven
trip codes. These features further establish the CH series of
products as “best-in-class.”
CHF series breaker include:
Mechanical flag for trip indication
Exclusive “Trip to OFF” and simple 1-Step breaker reset
Typical applications
Residential loadcenters
and meter breaker panels
Light commercial
distribution panels
Pool panels
Residential transfer
switch panels
Various OEM applications
AFCI diagnostic
trip codes
Thermal trip/manual
disconnect—the breaker
has detected an overload,
short circuit or was
manually turned off
Low current arc—an arc
has been detected due
to a break in a single
conductor
High current arc—an
arc has been detected
between two conductors
Short delay—an electronic
backup to the short-circuit
mechanism
Overvoltage—voltage
of 160 V rms or greater
Ground fault—current
has found an alternate
path to ground
Self test failure—the
breaker continually tests
the internal electronics
and software to ensure
that the arc fault
detection technology
is working properly
Thermal-magnetic breakers
Tri-Drive screw accepts flat,
Robertson or Phillips drivers,
making it easier
for electricians to install
Space-saving ¾-inch design
accommodates more breakers
per panel
Single- and two-pole breakers
up to 50 A
CH non-flag versions available
for 60–70 A in single-pole,
60–125 A in two-pole and up
to 100 A in three-pole
Standard features and benets
1
Type CH
Arc fault and ground fault breakers (AFCI/GFCI)
AFCI
1
Advanced electronics to
reduce unwanted tripping
from non-compliant devices
Standard LED indicates one
of seven trip codes to simplify
circuit diagnostics
Trip codes are stored
permanently into the breaker’s
memory, to help identify
“trip” history
Branch overvoltage protection
for sensitive electronics
Meets areas requiring AFCI
protection under the 2008
and all subsequent editions
of the NECT
Single-pole breakers
15 A and 20 A
GFCI
1
Single-pole breakers 15–30 A
5 mA protection per ULT 943
Optional plug-on neutral
Time savings up to 25% per
AFCI and GFCI installation
Improved wireway access
Easier troubleshooting due
to less wiring
Eliminates unwanted
tripping due to loose
pigtail connections
Standard features and benets
CHF circuit breakers
Plug-on neutral breakers
Pigtail breakers
Please reference catalog CA08100002E for additional ratings and configurations.
1
2
EATON Eaton circuit breakers and loadcenters