Specification

SPECIFICATIONS
• Single Pole and 3-Way (Primary Output Only).
• 8.3A (1000W) 120V AC 60 Hz.
• For Incandescent, Magnetic Low Voltage (MLV), Electronic Low Voltage (ELV), Fluorescent,
Compact Fluorescent, LED, Motors up to 1/6 HP.
• Includes Selectable and Dimmable Night Light.
NOTE - A Neutral Connection is required in the wallbox where the sensor will be installed.
DESCRIPTION
• This Sensor Wall Switch can replace a standard wall switch in any of the following applications:
• Single location – One single pole switch.
• Two location – One location is the sensor and the other location is a standard 3-Way switch. The
3-Way switch will only control the lights on the primary output.
• Both OS310R and VS310R have two outputs for controlling two separate loads.
• The OS310R automatically turns on output #1 (Primary) when a person enters the room.
• The VS310R requires manual activation to turn ON the lights for either output #1 or #2.
• Both OS310R and VS310R will automatically turn OFF both lights after a user selectable time delay.
• OS310R incorporates the ability to detect when rooms are only occupied very briefly and shortens the
time delay in order to save energy.
OS310R includes a light level adjustment for daylight to prevent motion from turning ON the lights if
the light level in the room is bright enough that lights are not needed.
• A green LED indicates the status of either load, acts as a locator light, and provides a momentary
flash to indicate that motion has been detected.
OPERATION INSTRUCTIONS
Auto ON Sensor – OS310R
• OS310R will turn on lights for Output #1 (Primary) automatically when a person enters the room
• OS310R will turn ON lights for Output #2 (Secondary) manually when its pushbutton is pressed.
• Lights for both outputs will turn OFF automatically when no motion is detected after a selectable
time delay.
• The selectable time delays are 5 seconds (Test Mode), 5 minutes (factory default), 15 minutes
and 30 minutes.
Manual ON Sensor – VS310R
• The VS310R must be turned ON manually with the ON/OFF button for each output.
Both light outputs will turn OFF automatically when no motion is detected after a selectable time delay.
• The selectable time delays are 5 seconds (Test Mode), 5 minutes, 15 minutes and 30 minutes (factory default).
• When the lights have turned OFF due to a lack of motion, the lights will turn back ON automatically if motion is detected within 10 seconds.
Night Light
• Press the Night Light lens momentarily to turn the Night Light ON or OFF.
• When the Night Light is ON, press and hold the Night Light lens to dim the Night Light to the desired brightness. Release when the desired brightness level is
reached. Press and hold again to brighten.
• The OS310R can also operate as a Manual ON sensor when the Night Light is ON. Refer to OS310R Special Modes for additional explanation.
OS310R SPECIAL MODES
Reverse Mode: The reverse mode is used when the lights must stay OFF in a room while motion is detected. If the lights are ON, a double tap of button 1 (Primary)
will turn off the lights and put the device into the Reverse Mode. This allows the lights to stay OFF as long as motion is detected. After a 5 minute delay the sensor
operation goes back to normal.
Manual ON Only mode: This mode may be selected to prevent motion from automatically turning ON the lights. Press and hold the ON/OFF button for 5 seconds
until the indicator LED blinks. Release the button while the LED is blinking. Repeat this procedure to restore normal operation. While the OS310R is in the manual
ON mode, it will behave like a VS310R.
Override Mode: Turns OFF all motion sensing and allows the device to be used as a regular ON/OFF switch or in the unlikely event of a failure of the motion sensor.
Press and hold the ON/OFF button for 10 seconds until the indicator LED blinks for the second time (the LED will also blink at the 5 second point). Release
the button while the LED is blinking. Repeat this procedure to restore normal operation. This mode also can be used on VS310R.
Manual ON Mode with Night Light ON: When in the auto ON mode, when the Night Light is turned on, the sensor will operate in the manual ON mode. This feature
can be enabled by pressing and holding the Night Light button for 5 seconds while the Night Light is OFF. The Night Light will blink after 5 seconds. Release the
button while the green LED is blinking. Repeat this procedure to restore normal operation.
INSTALLATION INSTRUCTIONS
WARNING
::
Turn OFF circuit breaker or remove fuse(s) and verify that power is OFF before wiring.
• Never wire any electrical device with power turned ON. Wiring the device with the power ON may cause permanent damage to the device and void the warranty.
• If you are unsure about any part of these instructions, or if the wiring does not match the descriptions given, you should call a qualified electrician.
CAUTION:
• Must be installed and used in accordance with all applicable electrical codes.
• If a bare copper or green ground connection is not available in the wallbox, contact a licensed electrician for installation. Do not install without a proper ground
connection.
• Do not exceed maximum device ratings.
• For use ONLY with permanently installed fixtures of these types: Incandescent/Halogen, Magnetic Low Voltage (MLV), Electronic Low Voltage (ELV), Fluorescent,
Compact Fluorescent, LED.
• May also be used with motors up to 1/6 HP.
• To avoid overheating and possible damage to other equipment, do not use to control receptacles.
• Use only #14 or #12 copper wire with these devices.
Installing OS310R & VS310R
Refer to the wiring diagrams and install the sensor according to these directions. You must verify that a neutral wire is available in the wallbox.
For single pole applications, wire the sensor switch according to wiring DIAGRAM 1 using the
wire nuts provided.
1. The sensor black wire and either of the yellow wires will connect to the hot wire (black) in
the wallbox.
2. The other sensor yellow wire will connect to the wire which goes to the Secondary light
fixture.
3. The sensor red wire will connect to the wire which goes to the Primary light fixture.
4. The sensor white wire will connect to the neutral wire (white) in the wallbox.
5. The sensor blue wire is not used and should be capped off with a wire nut.
6. The sensor green wire will connect to the ground wire in the wallbox.
7. Install the sensor loosely using the mounting screws provided.
8. Apply power temporarily and verify that the sensor works by pushing the ON/OFF button to
verify the lights turn on and off. If the lights do not work, then turn off the power and swap the
connections on the sensor black and red wires
9. Apply power again and verify that the sensor works by pushing the ON/OFF button to verify the
lights turn on and off.
10. Turn power OFF and go to COMPLETING THE INSTALLATION.
For 3-Way applications, wire the sensor switch according to wiring DIAGRAM 2 using the wire
nuts provided. The dual sensor must be placed at the end of the 3-Way circuit where the light
fixture wires are present in the wallbox.
1. Remove the existing switch in the location where the sensor will be installed.
a. Connect the sensor black wire and either one of the yellow wires to the black traveler
wire in the wallbox. If you cannot determine which wire is the traveler wire, contact a
licensed electrician.
C
atalog # OS310R Auto ON Sensor (Dual Output) Catalog # VS310R Manual ON Sensor (Dual Output)
DUALSWITCH-PTA (REV. A)
ENGLISH
IINN UU..SS..AA..::
Cooper Wiring Devices, 203 Cooper Circle, Peachtree City, GA 30269 • 866-853-4293
0
15’
MAJOR MOTION
1000 SQ. FT.
3
6’
0
COVERAGE PATTERN
MINOR MOTION
300 SQ. FT.
8
15’
8’
1
5’
DIAGRAM 1: SENSOR IN ONE LOCATION
OS310R or VS310R Sensor
Hot
(Black)
Hot
(Black)
Black
Ground
Green
Neutral
Neutral
White
Neutral
White
White
Primary Light
Fixture
Yellow
Output #2
Yellow
Output #2
Red
Output #1
Blue
3-Way
Secondary
Light
Fixture