INSTALLATION INSTRUCTIONS FOR FIXTURE
AS
SEMBLING THE FIXTURE (FIG. 1)
1. Shut off the power at the fuse box or circuit breaker. If necessary,
remove the old fixture from the ceiling including the mounting
hardware.
2. Carefully remove the new fixture from the carton and check that all
parts are included as shown in the illustration.
3. Adjust the arms to the desired position.
4. Thread the nipple (B) into the coupling (C) until snug;
5. Install the fabric shade (K) onto the bracket (Q) using ball screws (P);
6. Thread the nipple (F) into the coupling (E) and secure with the hex
nut.
7. Install the light bulb in accordance with fixture’s specifications. (DO
NOT EXCEED THE MAXIMUM WATTAGE RATING!) (NE PAS
DEPASSER LA PUISSANCE NOMINALE MAXIMALE!).
8.
Place the tube (G), check cover (H), flat washer (I), rubber washer (J),
glass diffuser (L) and flat washer (I) over the nipple (F) in this order
and secure with hex nut (O).
9. Place the cap (M) onto the nipple (F) and secure with finial (N).
MOUNTING THE FIXTURE (FIG. 2)
1. Thread the nipple (S) into the collar loop (T) until snug.
2. Thread the other end of nipple (S) into the cross bar (P).
3. Place lock washer (Q) and hex nut (R) over the end of nipple (S)
protruding through cross bar (P). Then thread hex nut (R) onto nipple
(S).
4. Take this crossbar assembly and mount to ceiling outlet box (V)
using outlet box screw (W). The side of cross bar marked
“GND” must face out.
5. Use proper chain pliers to open one end link of the chain
and connect to
the fixture loop (A). Close the link.
6. By measuring, determine the correct number of links needed for
proper hanging height. Using the chain pliers, disconnect and discard
the remaining chain.
7. Carefully lace the fixture wires through the chain (X).
8. Slip collar ring (Y) over the chain (X), then do the same with canopy (U).
9. Open the other end link of the chain (X) and connect to the collar loop
(T). Close the link.
10. Feed the fixture wires through the collar loop (T) and nipple (S) and
pull until tight.
CONNECTING THE WIRE (See fig.3)
1. At this point, connect the electrical wires as shown in Fig. 3, making
sure that all wire connectors are secured. If your outlet box has a
ground wire (green or bare copper), connect the fi
xture’s ground wire
to it. Otherwise, connect the fixture’s ground wire directly to the cross
bar using the green screw provided.
2. Tuck the wire connectors neatly into the ceiling outlet box
and raise the canopy(U) and collar ring (Y). Then thread collar
ring (Y) onto collar loop (T) protruding through canopy.
Your installation is now complete. Return power to the junction box and
test the fixture.
Fig.3
LOOP(A)
NIPPLE(B)
COUPLING(C)
COUPLING(E)
NIPPLE WITH HEX
NUT(F)
CHECK COVER(H)
RUBBER WASHER(J)
FABRIC SHADE(K)
GLASS DIFFUSER(L)
FLAT WASHER(I)
CAP(M)
FINIAL(N)
HEX NUT(O)
TUBE(G)
RUBBER WASHER(J)
FLAT WASHER(I)
BALL SCREW(P)
BRACKET(Q)
Fig. 1
Fig. 2
WARNING! SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER.
AVERTISSEMENT! COUPER LE COURANT AU NIVEAU DES FUSIBLES OU DU DISJONCTEUR.
-Crossbar
-Ground Screw
-Mounting screws (2)
Gauge 3.80MM
Notice: It is important to use proper chain pliers (not
included) to OPEN and CLOSE the chain included with
this fixture. Do not open them with other tools that may
twist or stress the chain links. It is important to use
proper chain pliers like the ones shown in the diagram.
Chain

Summary of content (1 pages)