Manual

20
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locater: Eccotemp.com/locater
Phone: 866-356-1992 | Email: Support@eccotemp.com | Address: 315 - A Industrial RD Summerville, SC 29483
HARDWIRING THE ELECTRICAL
CONNECTIONS:
• Wiring should be carried out by a qualied
electrician in accordance with local codes.
• The water heater requires 120 VAC/60Hz
and should be properly grounded.
• DO NOT connect grounding wire to water
pipes, gas pipes, telephone cables, lightning
conductor circuits and to grounding circuit
of other equipment that carry a ground-fault
interrupter.
• An ON/OFF switch must be provided and
installed for the incoming 120VAC power.
• Wire the water heater exactly as shown
below. A wiring diagram is also found inside
of the cover panel.
• A green screw is provided in the junction
box for grounding connection.
• Connect the live wire to black leg wire and
the neutral wire to the white neutral wire.
Electrical Connection
POWER CORD:
• The electric power supply requirement for
this water heater is 120 VAC/60HZ, 2 Amps.
• The water heater comes with a three (3) pin
power supply cord. Use only a power outlet
with a ground terminal.
• The installation of an electric leakage
breaker is recommended. (GFCI)
• Keep any excess of the power supply cord
on the outside of the water heater.
• If local codes require hardwiring, see
instructions for “Hardwiring the Electrical
Connections”.
WARNING :Field wiring connections and electrical grounding must comply with local codes, or in
the absence of local codes, with the la test edition of the National Electrical Code,ANSI/NFPA 70, or in
Canada, Canadian Electrical Code, CSA C22.1Part1.
WARNING: Shock hazard line voltage is
present. Before servicing the water heater, turn
off the electrical power to the water heater at the
main disconnect or circuit breaker. Failure to do so
could result in severe personal injury or death.
CAUTION: Label all wires prior to
disconnection when servicing controls. Wiring
errors can cause improper and dangerous
operation. Verify correct operation after servicing.
Electric Wiring Diagram
Ignition B
Ignition A
Feedback
On Off valve/
Sectional valve
Negative pole
for valve
Proportion valve
Earth wire
Temp
controller
Temp display
Wind switch
Water flow sensor
Power cord
Brown
Red
Yellow Green
Anti freezer-
Black
Black
Black
White
White
Yellow
Yellow
Yellow