A. Water Heater Location
Installed indoors.
Close to area of mostly used outlet.
Protected from freezing temperatures.
Proper clearance from combustible surfaces observed.
Sucient fresh air supply for proper operation of water heater.
Air supply free of corrosive elements and ammable vapors.
Provisions made to protect area from water damage.
Sucient room to service heater.
Combustible materials, such as clothing, cleaning materials, rags,
etc. clear of the heater and vent piping.
Water heater is properly attached to the wall.
B. Water Supply
Water supply has sucient pressure.
Air purged from water heater and piping.
Water connections tight and free of leaks
Water lter is clean and in place.
Materials used are as instructed in this manual.
Water pipes are insulated.
C. Gas Supply
Gas type matches rating plate.
Gas supply pressure is sucient for the water heater.
Gas line equipped with shut-o valve, union and sediment trap.
Approved pipe joint compound used.
Commercial leak detector or soap and water solution used to check all
connections and ttings for possible gas leak.
Gas Company inspected installation (if required).
D. Relief Valve
Pressure Relief Valve properly installed and discharge line run
to open drain
Discharge line protected from freezing.
E . Electrical Wiring
Voltage matches rating plate.
Water heater is properly grounded .
Wiring meets all local codes.
GFCI Protection where required.
Installation Checklist
Installation