DIAGRAMA ELÉCTRICO
MODELO iE-11 iE-15B
L1
T1
T2
R1
R2
L2
E
THERMAL CUT-OUT 95
CONTROL
SYSTEM
DISPLAY
SCREEN
INLET TEMP.SENSOR
FLOWMETER
OUTLET TEMP.SENSOR
REMARK: J:RELAY R:HEATING SYSTEM T:TRIAC
MODELO iE-15A iE-18
L1
L1'
T1
T2
R1
R2
L2
E
THERMAL CUT-OUT 90
CONTROL
SYSTEM
DISPLAY
SCREEN
INLET TEMP.SENSOR
FLOWMETER
OUTLET TEMP.SENSOR
REMARK: J:RELAY R:HEATING SYSTEM T:TRIAC
L2'
SENSORES DE TEMPERATURA DE SALIDA
SENSORES DE TEMPERATURA DE ENTRADA
MEDIDOR DE FLUJO
PANTALLA
SISTEMA DE
CONTROL
OBSERVACIÓN: J:RELAY R:HEATING SYSTEM T:TRIAC
LIMITACIÓN TÉRMICA 95 °C
SENSORES DE TEMPERATURA DE SALIDA
SENSORES DE TEMPERATURA DE ENTRADA
MEDIDOR DE FLUJO
PANTALLA
SISTEMA DE
CONTROL
OBSERVACIÓN: J:RELAY R:HEATING SYSTEM T:TRIAC
LIMITACIÓN TÉRMICA 90 °C