Street Light Bridge Integrator’s Guide 55
1. Right-click the SmartServer icon, select Setup, and select Power Line
Repeating Analysis from the shortcut menu. Alternatively, you can click
the Tools icon and select Power Line Repeating Analysis.
2. The Power Line Repeating Analysis Web page opens.
The rows in this Web page represent established repeating paths between
the listed devices. The target device in a repeating chain is listed
furthest to the right. The current chain of repeating devices used to relay
messages to the target device are listed to the left of the target device.
The repeating chains lead back to the SmartServer, which is listed
furthest to the left, in the column titled Center.
The SmartServer is always listed in the column titled Center because all
network messages originate from its local LonTalk (ISO/IEC 14908-1)
device (Net/LON/LtaLdv).
The repeating chains of the first 20 repeating devices listed in the tree
view are displayed in this Web page. Devices that have been installed
successfully are marked black, devices in the process of being installed
are marked orange, and devices with communication failures or other
errors are marked red.
To view the repeating chain of another device, click that device in the
tree. To view multiple additional devices, click a device in the tree, and
then either hold down CTRL and click all other additional devices to be
viewed, or hold down SHIFT and select another device to view the entire
range of additional devices.