84 Controlling a Street Lighting Network
illuminates them at the beginning of the morning and evening rush hours, and a
third exception that dims the lights at sunrise and sundown.
To open an Event Scheduler application, you must first create a Scheduler
functional block, if the available functional blocks are not already displayed in
the tree view for the i.LON App (Internal) device. After you create the Scheduler
functional block, the functional block appears on the SmartServer tree below the
i.LON App (Internal) device. You can then click the functional block and begin
configuring the Event Scheduler application.
To create a Scheduler functional block and open the application, perform the
following steps:
1. Expand the Net network icon in the SmartServer tree, and expand the
LON channel to show the i.LON App (Internal) device.
2. Right-click the i.LON App (Internal) device, and select Add Functional
Block from the shortcut menu.
3. The Add Functional Block dialog opens.