MAINTENANCE PROCEDURE NOTES:
1 Low evaporative fuel tanks DO NOT require regular maintenance to
maintain emission integrity.
2 See your dealer for maintenance.
3 Replacement is recommended based on the finding of damage or wear
during inspection.
Throttle Connecting Rod
Level 1.
1. Apply grease to throttle
connecting rod at location (A).
Air Filter
Level 1.
Muffler Spark Arrestor
Inspect/Clean
2
3
Cylinder Exhaust Port
Inspect/Clean/De-carbon
2
Yearly
Fuel Filter
Inspect/Replace
3
1
Fuel Cap Gasket
Replace
3
Parts Required: Lithium Based Grease