Power Blower Operator's Manual MODELS PB-500H PB-500T warning Users of this equipment risk injury to themselves and others if the unit is used improperly and/or safety precautions are not followed. ECHO provides an operator’s manual. It must be read and understood for proper and safe operation. Failure to do so could result in serious injury.
Introduction Welcome to the ECHO family. This ECHO product was designed and manufactured to provide long life and on-thejob-dependability. Read and understand this manual. You will find it easy to use and full of helpful operations tips and SAFETY messages. the operator's manual Keep it in a safe place for future reference. Contains specifications and information for safety, operation, maintenance, storage, and assembly specific to this product.
Power Blower Operator's Manual Safety manual safety symbols and important information Throughout this manual and on the product itself, you will find safety alerts and helpful, informational messages preceded by symbols or key words. The following is an explanation of those symbols and key words and what they mean to you.
Physical Condition Your judgment and physical dexterity may not be good: • if you are tired or sick, • if you are taking medication, • if you have taken alcohol or drugs. Operate unit only if you are physically and mentally well. Eye Protection Wear eye protection that meets ANSI Z87.1 or CE requirements whenever you operate the unit. Hand Protection Wear no-slip, heavy-duty work gloves to improve your grip on the blower handle.
Power Blower Operator's Manual Repetitive Stress Injuries It is believed that overusing the muscles and tendons of the fingers, hands, arms, and shoulders may cause soreness, swelling, numbness, weakness, and extreme pain in those areas. Certain repetitive hand activities may put you at a high risk for developing a Repetitive Stress Injury (RSI). An extreme RSI condition is Carpal Tunnel Syndrome (CTS), which could occur when your wrist swells and squeezes a vital nerve that runs through the area.
equipment check WARNING Use only ECHO approved attachments. Serious injury may result from the use of a non-approved attachment combination. ECHO, INC. will not be responsible for the failure of cutting devices, attachments or accessories which have not been tested and approved by ECHO. Read and comply with all safety instructions listed in this manual and safety manual. • • • • Check unit for loose/missing nuts, bolts and screws. Tighten and/or replace as needed.
Power Blower Operator's Manual Description PB-500H Locate these safety decals on your unit. Make sure the decals are legible and that you understand and follow the instructions on them. If a decal cannot be read, a new one can be ordered from your ECHO dealer. See PARTS ORDERING instructions for specific information.
1. SAFETY DECAL - Lists important safety precautions. 2. SPARK PLUG - Provides spark to ignite fuel mixture. 3. Spark arrestor muffler or spark arrestor muffler with catalyst - The muffler or catalytic muffler controls exhaust noise and emission. The spark arrestor screen prevents hot, glowing particles of carbon from leaving the muffler. Keep exhaust area clear of flammable debris. 4. RECOIL STARTER HANDLE - Pull recoil handle slowly until starter engages, then quickly and firmly.
Power Blower Operator's Manual PB-500T 1 7 2 Hot Decal (near muffler) 6 5 4 3 10 8 11 12 9 13 15 14 General Warning Decal (located on blower housing) Sound Label (located on blower housing) dB(A) 70 Category II Measured at 50 ft. (15m) per ANSI B175.
1. SAFETY DECAL - Lists important safety precautions. 2. SPARK PLUG - Provides spark to ignite fuel mixture. 3. Spark arrestor muffler or spark arrestor muffler with catalyst - The muffler or catalytic muffler controls exhaust noise and emission. The spark arrestor screen prevents hot, glowing particles of carbon from leaving the muffler. Keep exhaust area clear of flammable debris. 4. RECOIL STARTER HANDLE - Pull recoil handle slowly until starter engages, then quickly and firmly.
Power Blower Operator's Manual Contents PB-500H ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ 1 - Power Head 1 - Flex Pipe 1 - Pipe w/swivel 1 - Straight Pipe 1 - Straight Pipe w/decal 1 - Operator's Manual 1 - Emission Control Warranty Statement 1 - Warranty Registration Card 1 - Plastic Bag 2 - Clamps w/screws 1 - Stick Handle 1 - Bolt 6x45 1 - Washer 6 1 - Wing nut 1 - Echo Power Blend XTM 2-stroke oil sample ECHO LIMITED WARRANTY STATEMENT FOR PRODUCT SO
Assembly PB-500H WARNING B A A Never perform maintenance or assembly procedures with engine running or serious personal injury may result. install blower pipes / stick handle 1. Assemble clamps (A) onto both ends of flexible pipe (B). 2. Assemble straight pipe with swivel (C) into flexible pipe (B). 3. Assemble flexible pipe (B) to elbow (D) on blower. NOTE A light lubricant may be used to ease assembly of flexible pipe to blower elbow. D C A B A 4. Tighten clamps (A). 5.
Power Blower Operator's Manual 13 PB-500T WARNING G Never perform maintenance or assembly procedures with engine running or serious personal injury may result. install blower pipes (t) 1. Place guide loop (G) across clamp, and turn until clip fully engages clamp band. G A B A NOTE Clamp with cable guide loop (G) fits elbow end of flexible pipe (B). 2. Assemble clamps (A) onto both ends of flexible pipe (B). 3. Assemble flexible pipe (B) to elbow (D) on blower.
Operation WARNING Moving parts can amputate fingers or cause severe injuries. Keep hands, clothing and loose objects away from all openings. Always stop engine, disconnect spark plug, and make sure all moving parts have come to a complete stop before removing obstructions, clearing debris, or servicing unit. Blower housing may contain shredder blades and other sharp edges that can cause serious injuries if touched, even if engine is off and blades are not moving.
Power Blower Operator's Manual 15 Handling Fuel DANGER Fuel is VERY flammable. Use extreme care when mixing, storing or handling or serious personal injury may result. • Use an approved fuel container. • DO NOT smoke near fuel. • DO NOT allow flames or sparks near fuel. • Fuel tanks/cans may be under pressure. Always loosen fuel caps slowly allowing pressure to equalize. • NEVER refuel a unit when the engine is HOT or RUNNING! • DO NOT fill fuel tanks indoors.
starting cold engine • Recoil starter: Use short pulls - only 1/2-2/3 of rope length for starting. Do not allow the rope to snap back in. Always hold the unit firmly. • (PB-500H): Rotate spring loaded throttle arm downward to a comfortable operating position. PB-500H PB-500H 1. Throttle Lever Move throttle position lever (A) midway between idle and full throttle positions. PB-500T PB-500T 1.
Power Blower Operator's Manual starting warm engine The starting procedure is the same as Cold Start except DO NOT close the choke. PB-500H PB-500H 1. Throttle Lever Move throttle position lever (A) midway between idle and full throttle positions. PB-500T A PB-500T 1. Throttle Position / Stop Switch Button Slide Throttle position / Stop switch Button(A) back to idle position. PB-500H, PB-500T 2.
operating blower WARNING Engine exhaust IS HOT, and contains Carbon Monoxide (CO), a poison gas. Breathing CO can cause unconsciousness, serious injury, or death. Exhaust can cause serious burns. ALWAYS position unit so that exhaust is directed away from your face and body. WARNING Always wear safety glasses, hearing protection, a face filter mask and take all safety precautions or serious personal injury may result. Do not point the blower pipe in the direction of people or pets.
Power Blower Operator's Manual 19 Maintenance WARNING Moving parts can amputate fingers or cause severe injuries. Keep hands, clothing and loose objects away from all openings. Always stop engine, disconnect spark plug, and make sure all moving parts have come to a complete stop before removing obstructions, clearing debris, or servicing unit. Allow unit to cool before performing service. Wear gloves to protect hands from sharp edges and hot surfaces.
air filter Level 1. Parts required: RepowerTM Tune Up Kit NOTE Clean daily. 1. Close choke (Cold Start Position [ ]). This prevents dirt from entering the carburetor throat when the air filter is removed. Brush accumulated dirt from air cleaner area. 2. Remove air filter cover. Brush dirt from inside cover. 3. Remove air filter and lightly brush debris from filter. Replace filter if it is damaged, fuel soaked, very dirty, or the rubber sealing edges are deformed. 4.
Power Blower Operator's Manual spark plug Level 1. Parts Required: RepowerTM Tune Up Kit IMPORTANT Use only NGK BPM8Y spark plug (BPMR8Y in Canada) otherwise severe engine damage may occur. 1. Remove spark plug , and check for fouling, worn and rounded center electrode. 2. Clean the plug or replace with a new one. DO NOT sand blast to clean. Remaining sand will damage engine. 3. Adjust spark plug gap by bending outer electrode. 4.
Cleaning Cylinder Fins 1. Disconnect spark plug lead from spark plug. 2. Remove engine cover (five screws), pull cover away from engine. A 3. Clean cylinder fins (A) to allow cooling air to pass freely. 4. Replace cover and tighten screws. 5. Connect spark plug lead. exhaust system Spark Arrestor Screen Level 2. Parts Required: Spark arrestor screen, Gasket IMPORTANT Carbon deposits in muffler will cause a drop in engine output and overheating.
Power Blower Operator's Manual 23 Exhaust Port Cleaning Level 2 Parts Required: As needed: Muffler gasket 1. Remove spark plug lead from spark plug, and remove engine cover. 2. Place piston at top dead center. Remove muffler (A) and muffler gasket (B ). A 3. Use a wood or plastic scraping tool to clean deposits from cylinder exhaust port. IMPORTANT Never use a metal tool to scrape carbon from the exhaust port. Do not scratch the cylinder or piston when cleaning the exhaust port.
carburetor adjustment Engine Break-In New engines must be operated a minimum duration of two tanks of fuel break-in before carburetor adjustments can be made. During the breakin period your engine performance will increase and exhaust emissions will stabilize. Idle speed can be adjusted as required. High Altitude Operation This engine has been factory adjusted to maintain satisfactory starting, emission, and durability performance up to 1,100 feet above sea level (ASL) (96.0 kPa).
Power Blower Operator's Manual 25 Troubleshooting TROUBLESHOOTING CHART Problem Engine cranks starts hard/ doesn't start C h eck Status Fuel at carburetor No fuel at carburetor Fuel at cylinder C au se Remedy Fuel strainer clogged Fuel line clogged Carburetor Clean or replace Clean or replace See your Echo dealer No fuel at cylinder Carburetor See your Echo dealer Muffler wet with fuel Fuel Mixture too rich Open choke Clean/replace air filter Adjust carburetor See your Echo dealer Spark a
Storage WARNING During operation the muffler or catalytic muffler and surrounding cover become hot. Always keep exhaust area clear of flammable debris during transportation or when storing, otherwise serious property damage or personal injury may result. Long Term Storage (Over 30 Days) Do not store your unit for a prolonged period of time (30 days or longer) without performing protective storage maintenance which includes the following: 1.
Power Blower Operator's Manual 27 Specifications MODEL ���������������������������������������������������� PB-500H, PB-500T Length PB-500H ������������������������������������������ 380mm (15.0 in.) Length PB-500T ������������������������������������������� 328mm (12.9 in.) Width PB-500H ������������������������������������������� 545 mm (21.5 in.) Width PB-500T ������������������������������������������ 470 mm (18.5 in.
Warranty Statements ECHO LIMITED WARRANTY STATEMENT FOR PRODUCT SOLD IN USA AND CANADA BEGINNING 01/01/2010 ECHO'S RESPONSIBILITY ECHO Incorporated’s Limited Warranty, provides to the original purchaser that this ECHO product is free from defects in material and workmanship.
Power Blower Operator's Manual 29 PURCHASED REPAIR PARTS, SHORT BLOCKS AND ACCESSORIES • 90-day residential, or non-income producing warranty • 30-day commercial, institutional, agricultural, industrial, income producing, or rental application warranty ATTENTION TWO-STROKE ENGINE POWER PRODUCT OWNERS This ECHO two-stroke engine power product is a quality-engineered unit which has been manufactured to exact tolerances to provide superior performance.
notes
Power Blower Operator's Manual notes 31
Servicing Information parts/serial number Genuine ECHO Parts and ECHO REPOWER™ Parts and Assemblies for your ECHO products are available only from an Authorized ECHO Dealer. When you do need to buy parts always have the Model Number, Type and Serial Number of the unit with you. You can find these numbers on the engine housing. For future reference, write them in the space provided below. Model No. _________________SN.