Owners Manual

11
To Connect the LP Gas Supply:
1. Ensure the 20 lb. LP tank valve is fully closed. To do so, make sure the tank handle is
turned all the way clockwise. You should not hear a hissing noise or smell propane.
2. All gas control (burner) knobs must be in the off position.
3. Align the 3/8” brass coupling nut with the LP tank threads; turn the coupling nut
clockwise by hand. Note that the fittings have flared ends and do not require any
modifications or sealant. Do not overtighten the coupling nut connection as it may
cause damage or strip the threading.
4. Open the LP tank valve by turning the handle counterclockwise.
5. Using a soapy water mixture in a spray bottle, check for leaks at all joints and
connection points. Bubbles should not form in the soapy water mixture. See the section
titled, “Checking for Gas Leaks” in this manual for further instructions and details.