Owner's Manual

4
Important: Do not remove any safety, warning, or product information labels from your portable
fridge / freezer.
Warning: Use two or more people to move and handle this unit. Failure to do so can result in
back or other injury. Carefully remove the packaging materials and any shipping tape before
use.
Handling and Installation
1. Remove all interior and exterior packaging.
2. Position the freezer in a dry and well-ventilated place. Keep the freezer away from direct
sunlight, heaters, and corrosive gas.
3. Clean the interior surface with a small amount of lukewarm water and a soft cloth.
4. When inserting the AC power cord into the power socket. Make sure the power socket is a
grounded 115V~AC / 60 Hz socket. Also make sure that the unit’s grounding prong is not
damaged.
5. When moving the freezer, always use both handles to carry the unit as level as possible in
order to protect the compressor and the sealed system.
Operation
Test Run: DC Input Power
The control system allows for the voltage cut-out to be set to three (3) different settings
depending on the environment & situation that the appliance is being operated in. Low voltage
supply to the appliance can result in poor cooling performance and damage to the supply
battery.
When using 12V DC, the digital readout will show the factory setting 10.0V DC. To ensure that
suitable battery voltage can be maintained the controller has been programmed to offer three
(3) cut-out levels: 11.8, 10.7, and 10.0V DC.
When using 24V DC, the digital readout will show the factory setting 22.2V DC. To ensure that
suitable battery voltage can be maintained the controller has been programmed to offer three
(3) cut-out levels- 25.0, 23.5 & 22.2V DC.
To set the battery cut-out to the required level follow these steps:
1. Press “Set” to switch from temperature setting to low-voltage setting. Press once to set the
temperature, and press again to set the low voltage cut-out.
2. Push the “+” or “-” to adjust the setting. The display will flash four (4) times with the
selected setting. To check press “SET” once and the selected setting will flash and then
return to current voltage input.
When the appliance is disconnected from the power source the battery cut-out remains at its
last setting.
Note: When inserting the DC power cord, make sure the input is a 12V~DC / 24 V power
source.