Installation Sheet

Table Of Contents
14
Control Panel (Behind Front Panel)
1. Ice Full (Red) LED: Ice Full indicator light.
When this LED is lit, the ice storage bin is full of ice or there is something obstructing the ice full
sensor. The unit will stop producing ice. When ice cubes are removed from the ice storage bin,
clearing the ice full sensor, the red LED will keep flashing for 3 minutes. Then the unit will
restart and return to the ice making mode.
2. Ice Making (Green) LED: Ice Making indicator light.
When this LED is lit or flashing, the unit is working in the Ice Making mode.
3. Ice Harvest (Yellow) LED: Ice Harvest indicator light.
When this LED is lit, the unit is working in the Ice Harvest mode.
4. Mode button: Mainly for service.
When this button is pressed, the unit can change from Ice Making mode to Ice Harvest mode,
or from Ice Harvest mode to Ice Making mode. The mode can be determined from the status of
the green and yellow LEDs.
5. Ice Size Adjust button: When this is pressed and held for 3 seconds, the unit will enter the Ice
Size Adjustment mode. Once in this mode, press 'Clean' to decrease the ice size, or press
'Mode' to increase the ice size. Please note that there are five larger ice sizes and five smaller
ice sizes from the default setting. The current ice size can be determined from the status of the
red, green, and yellow LEDs. The green, yellow, and red LEDs flashing synchronously indicates
the default ice size. When decreasing the ice size with the ‘Clean’ button, the red LED will flash
once and the green LED will flash continuously. The red and green LEDs flashing
synchronously indicate that the smallest ice size has been reached. When increasing the ice
size with the ‘Mode’ button, the yellow LED will flash once and the green LED will flash
continuously. The yellow and green LEDs flashing synchronously indicate that the largest ice
size has been reached.
Important:
It’s not recommended that the ice size be adjusted unnecessarily since this could damage the
machine’s controls
Do not let water contact the control box.
If the red, green, and yellow LEDs are flashing together, the machine is not working. The major
fuse of the control box has failed. Call for service.
Ice
-harvest
Ice-making
Ice-full
M
ode
Cle
an
Adjust
0
0
0
0
0
0