Product Overview

Information and product specifications contained in this document are subject to change without notice.
Specifications
Electric Tankless Water Heater
LavAdvantage
Point-of-Use Microprocessor Temperature Control
Applications
Lavatory sinks
Multi lav congurations ideal for sensor or metering faucets
(ML option - 110°F max.)
Emergency eye wash fountains (EE option - 90°F max.)
Performance Features
Industry’s lowest activation with 0.2 GPM turn on ow
Active energy management with power modulating controls
Microprocessor temperature control with digital display for
thermostatic accuracy +/-1°F
Field adjustable set point range between 70-140°F. Factory
set at 120°F (3.5kW and below set at 105°F). Special settings
of higher or lower range available based on options (see
Specication Options)
Silent Operation (except for SPEX0122240T)
Mounts in any orientation
Proprietary purge technology engages upon installation to help
protect against dry-re occurrence
Accessible diagnostic feature displays error codes
Cut energy waste – Flow switch activates heater only on
demand (no standby heat loss)
Save water and time by installing unit at point-of-use to eliminate
long pipe runs
Eliminate costly mixing valves (check local codes)
Continuous hot water – No storage capacity to run out
Easy installation. Only one cold or hot water line need be
brought to installation – integral compression ttings are 3/8" (no
sweat connections)
Reduces installation cost and materials. No T&P relief valve
needed (check local codes)
High temperature limit switch (ECO)
Booster up to 180°F (S option)
Warranty, ve (5) years limited on leaks, one (1) year parts
Compact size ts almost anywhere for exible installation;
suitable for ADA compliant facilities
Product Specications
Dimensions: 9.75" x 5.25" x 3"
Weight: 4 lb
Cover: ABS UL rated 94 5VA
Color: White
Adj. Temperature Range: 70°F-140°F
Min. Dynamic Operating Pressure:
35 PSI
Max. Dynamic Operating Pressure: 150 PSI
Element: Replaceable Ni Chrome cartridge insert
Fittings: 3/8" compression fittings
UL listed file number: E86887
U.S. Patent #’s: 4,762,980 and 4,960,976
Special Design Service
Inquiries for units for unique applications are welcome.
Call our Technical Service department at 1-800-543-6163.
Suggested Specication
Tankless water heater shall be an Eemax LavAdvantage model
number SPEX___________.
Unit shall have ABS-UL 94 5VA rated cover. Unit shall have
0.2 GPM turn on. Unit shall allow mounting in any direction.
Element shall be replaceable cartridge insert. Unit shall have
replaceable lter in the inlet connector. Element shall be iron free,
Nickel Chrome material. Tankless water heater to utilize complex
algorithm, actively managing power application to real time
system demand. Integrated ow meter, along with inlet and outlet
temperature sensors provide data which allows the unit to instantly
adapt to variations in input parameters. Heater shall be tted with
3/8" compression ttings to eliminate need for soldering. Maximum
operating pressure of 150 PSI. Accessible diagnostic features to
include error/fault display. Hot water storage tanks prohibited. Unit
shall be Eemax or approved equal.
Tankless water heater user interface must have the following
capabilities:
Selectable display including Celsius /Fahrenheit, set point, ow
rate, inlet temperature outlet temperature, power factor
Capable of displaying ow rate in gallons per minute & liters per
minute
Diagnostic features to include error/fault display
Control board must maintain error/fault history of 5 events
Specication options to be included with SPEX models:
_____ EE
Emergency Eyewash. Meets ANSI tepid water
requirements. Factory set to 90°F. Max temp. 90°F.
_____ ML
Multiple Lavatory. Factory set to 110°F. Max
temp. 110°F
_____ S Sanitation. Factory set to 120°F. Max temp. 180°F.
_____ N4 NEMA 4 waterproof cabinet w/powder coat nish
_____ N4X NEMA 4 stainless steel waterproof corrosion-
resistant cabinet
*The wetted surface of this product
contacted by water contains less than
0.25% lead and meets ANSI/NSF 372
Note: For optimum performance, mounting location should
be located within 2 feet of fixture.