User manual

Clearing House Codes: The house codes memorised can be deleted (i.e. the
RadioLINK Bases can be uncoded) by pressing and holding the House Code
switch on for about 6 seconds. The amber light will come on and then flash slow-
ly to indicate the smoke alarm has been returned to the default factory settings.
(this also clears the Repeater function).
Repeater Function: The RadioLINK Base receives and then re-broadcasts the
varoius RF signals, so effectively boosting the signal range.
Activating the Repeater Function: Press and hold the test button until the alarm
sounds and the amber light comes on, then immediately (while the light is on) press
and hold the House Code switch until the amber light flashes slowly. The amber
light will flash 15 times to indicate that the RadioLINK Base is now a Repeater
Base.
De-activating the Repeater Function: Press and hold the test button until the
alarm sounds and the amber light comes on, then immediately press and hold the
House Code switch until the amber light flashes slowly. The amber light will flash
only 3 times to indicate that the RadioLINK Base is now no longer a Repeater
Base.
16