User manual

depleted so leave the unit on mains power for 2
hours to charge and test again.
Similarly, install all the other Smoke/Heat Alarms
with their Ei168 RadioLINK Bases.
10. Press and hold the House Code switch on the
side of any one of the RadioLINK Bases as
shown in figure 6 with a small screwdriver until
the amber light turns on. Release the switch and
the light will flash quickly a few times. The amber
light will then flash every 5 seconds. Repeat this
action on all other RadioLINK Bases in the
property within 15 minutes (before the timeout
period expires).
(If any other RadioLINK accessories are to be used they
must also be put into the house code mode at this time
see their instructions leaflets for details).
11. Check that all RadioLINK Bases have com-
municated with each other by counting the num-
ber of times the amber light flashes on each
base in turn. For example, 3 units in the system
should have 3 flashes every 5 seconds, 4 units
should have 4 flashes and so on. (If there is a problem see Section 5)
12. Check the radio link communication by pressing the test/hush button for up to
6
RECHARGEABLE
CELL "ON" SWITCH
Figure 7
AMBER LIGHT
INSERT SCREWDRIVER TO
TURN ON HOUSE CODE SWITCH
Figure 6