10. Charger indicator
Indicator status
Explanations and actions
Red LED Green LED
Off Flashing Ready for use
The charger is connected to the mains and is ready for use; there is no
battery pack in the charger
On Off Charging
The charger is charging the battery pack in quick charge mode.
Off On The battery is charged and ready for use.
Action:
Take the battery pack out of the charger. Disconnect the charger from
the mains supply.
Flashing Off Adapted charging
The charger is in gentle charging mode.
For safety reasons the charging is performed less quickly and takes
more time. The reasons can be:
- The rechargeable battery has not been charged for a very long time.
- The battery pack temperature is outside the ideal range (between 10°
C and 45° C).
Action:
Wait for the charging to be completed; you can still continue to charge
the battery pack.
Flashing Flashing Fault
Charging is no longer possible. The battery pack is defective.
Action:
Never charge a defective battery pack.
Take the battery pack out of the charger.
On On Temperature fault
The battery pack is too hot (e.g. due to direct sunshine) or too cold
(below 0° C).
Action:
Remove the battery pack and keep it at room temperature (approx. 20°
C) for one day .