Operator`s manual

A-61371 April 2010 D-5
U6: Year, Month and Date Set mode —the print pattern for the Date
Print function can be set with this function.
1. Select U6 in the User mode.
2. Press the Exposure Mode key to display d*.
3. Press the Exposure Adjustment key (Darker or Lighter) to select
the desired setting value.
4. Press the Start key to validate the setting.
Year: 4 digits of dominical year
Month: 2 digits
Day: 2 digits
Hour: 2 digits (24-hour system)
Minutes: 2 digits
U7: Imprint mode set — when the time of day is incorrect, use the
Date Print function to set the correct time.
1. Select U7 in the User mode.
2. Press the Exposure Mode key. When the Exposure Mode key is
pressed, both the Exposure Display and Multi-Print Display light up
steadily.
NOTE: In the initial condition, the year default setting is displayed.
Each time the Darker key is pressed, the Exposure Display scrolls
upward to select the current setting mode in the following order:
Month, Day, Hours, Minutes.
Each time the Lighter key is pressed, the Exposure Display scrolls
downward to select a setting mode.
Code Setting Value Initial Setting
d0 Year, month, day (2004.05.15)
d1 Month day year (05 15 2004) *(120V)
d2 Day month year (15 05 2004) *(200V)
d3 Month, day hours:minutes (05.15 13:45)
(Year)
(Month)
(Hour)
(Minute)
(Day)