36" Dual-Fuel Freestanding Range Specifications
Product Weight – 360 Lbs.
Single phase 4-wire cable, 240 Volt, 60 Hertz AC only electrical supply
with ground required on separate circuit fused on both sides of line.
Connected Load (kW Rating) @ 240 / 208 Volts = 5.5 / 4.1 kW
Amps @ 240 / 208 Volts = 23 / 20 Amps
Recommended Circuit Breaker – 30 Amps
Always consult local and national electric and gas codes.
Make sure wall coverings around range can withstand heat generated
by range.
Linoleum or any other synthetic floor covering located beneath range,
must be capable of withstanding minimum heat of 90° F above room
temperature without shrinking, warping or discoloring. Insulating pad
or 1/4" thick plywood required between range and a carpeted floor.
Do not obstruct flow of combustion air at oven vent nor around base
or beneath lower front panel of range. Range requires fresh air for
proper burner combustion.
Do not install range beneath any downward-blowing, overhead
vent hood or air curtain.
Range ships with 3/4" factory regulator.
LP Gas conversion kit supplied.
Overhead cabinetry should not exceed a 13" maximum depth.
Allow 36" minimum clearance between top of rangetop and bottom of
unprotected wood or metal overhead cabinetry.
Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than maximum
width of appliance.
Allow 7" minimum clearance from edge of rangetop to nearest combustible
wall on either side of unit.
To reduce risk of fire when using overhead cabinetry, install vent hood
that projects horizontally a recommended minimum of 5" beyond
bottom of cabinets.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxicon.com for detailed instructions.
36" Dual-Fuel Freestanding Range
E36DF76TPS professional series
36" Dual-Fuel Freestanding Range
E36DF76TPS
24"
min.
24
1
/
2
"
max.
12"
12"
*Minimum distance required
between cooking surface
and cabinet bottom
25"
13"
max.
C
L
36"
min.*
Side
Front
35
7
/8"
41
5
/8"
min.
42
5
/8"
max.
1
9
/
16
"
28
3
/4"
27
1
/2"
25
7
/8"
Optional 9"
35
3
/4"
min.
36
3
/4"
max.
7
3
/4"
Optional 12"
Power
supply
connection
(right
bottom
rear*)
Gas inlet
location
(left
bottom
rear*)
1
1
/2"
Depth
including
oven door
in 90°
open
position –
48
3
/8"
Adjustable legs
Standard 6"
backsplash
Wall
36"
min.
36
1
/16"
min.
35
3
/
4
"
min.
36"
stand.
8"
8"
Shaded area is suggested location for
electrical wall outlet which may also be
located on wall in lower left corner of
adjacent right cabinet. (All dimensions
for outlet locations are maximum.)
Hatched area is suggested gas supply/
shut-off valve location. (Supply piping can
enter through cabinet side wall.)
Minimum
7" clearance
required
from cooking
surface to
adjacent side
walls or other
vertical surfaces
or structures
such as cabinets
18"
min.
18"
min.
5"
max.
14"
*when viewed
from front