Finding Information Please read and save this guide Thank you for choosing Electrolux, the new premium brand in home appliances. These Installation Instructions are part of our commitment to customer satisfaction and product quality throughout the life of your new appliance. We view your purchase as the beginning of a relationship. To ensure our ability to continue serving you, please use this page to record important product information.
Safety Important Recognize labels Safety safety Instructions symbols, words and Safety items throughout this manual are labeled with a WARNING or CAUTION based on the risk type as described below: /_X WARNmNG /_ CAUTmON This symbol alerts you to situations that may cause serious body harm, death or property damage. This symbol alerts you to situations that may cause bodily injury or property damage. Read all of the following or in Canada, CAN/ACG B149.1-2000.
installation Electrical Electrical system requirements Requirements requirements for electric d_jer: CIRCUIT - individual 30 amp. branch circuit fused with 30 amp. time delay fuses or circuit breakers. Use separately fused circuits for washer and dryer. DO NOT operate a washer and a dryer on the same circuit. POWER SUPPLY - 3-wire or 4-wire, 240 volt, single phase, 60 Hz, Alternating Current. with clothes dryers. For 3-wire cord connection instructions see ELECTRICAL CONNECTIONS FOR A 3-WIRE SYSTEM.
Installation Gas supply Requirements requirements . The gas supply line MUST have an individual shutoff valve. 5. A 1/8 inch (0.32 cm) N.RT. plugged tapping, accessible for test gauge connection, MUST be installed immediately upstream of the gas supply connection to the dryer. 1. Installation MUST conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1 (latest edition). 2. The gas supply line should be 1/2 inch (1.27 cm) pipe. 3.
installation Requirements Exhaust system requirements, continued MAXIMUM The dryer must be connected to an exhaust outdoors. Regularly inspect the outdoor exhaust opening and remove any accumulation of lint around the outdoor exhaust opening and in the surrounding area. LENGTH of 4" (10.2cm) Rigid Metal Duct Z VENT HOOD TYPE (Preferred) o E* 2.5" 4" (10.2cm) Iouvered (6.35cm) 0 125 ft. (38.10m) 110 ft. (33.53m) 1 115 ft. (35.05m) 100 ft. (30.48m) 2 105 ft. (32.00m) 90 ft. (27.
Installation Exhaust system requirements, Requirements continued Compression or crimping of the exhaust system will cause an increase in vent restriction. The exhaust system should be inspected and cleaned a minimum of every 18 months with normal usage. The more the dryer is used, the more often you should check the exhaust system and vent hood for proper operation. . . Connect an inclined or digital manometer between the dryer and the point the exhaust connects to the dryer.
installation Cmearance Requirements requirements MINIMUM INSTALLATION CLEARANCES -Inches SIDES REAR TOP (cm) FRONT Alcove 0" (0 cm) 0" (0 cm)* 0" (0 cm) n/a UnderCounter 0" (0 cm) 0" (0 cm)* 0" (0 cm) n/a Closet 0" (0 cm) 0" (0 cm)* 0" (0 cm) 1" (2.54 cm) For other than straight back venting, a quick-turn 90 ° dryer vent elbow must be installed to achieve 0" (0 cm) iNSTALLATiON iN A RECESS OR CLOSET 1.
Installation Installed dryer Requirements dimensions 50.6" (128.5cm)* to clear open door 27.00 -(68.5cm) 31.59" (8Ocm)* to front of closed door 38.00" (96.5cm) electrical supply on rear of unit 53.00" (134.5cm) freestand dryer on floor optional pedestal height for rear vent gas supply pipe on rear 18.25" 15.25" (46.5cm) (4t.5cm) floor line * To obtain these minimal depth dimensions, dryer must with a quick-turn 90 ° elbow. Connection of water inlet (2 cm) to installation depth.
"l installation instructions The following are specific requirements for proper and safe electrical installation of your dryer. Failure to follow these instructions can create electrical shock and!or a fire hazard. ELECTRICAL SHOCK HAZARD This appliance MUST be properly grounded. Electrical shock can result if the dryer _snot properly grounded. Follow the instructions in this manual for proper grounding. Do not use an extension cord w_th this dryer.
Installation Grounding requirements o Electric dryer instructions (Canada} For a grounded, cord-connected dryer: 1. The dryer MUST be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of electrical shock by a path of least resistance for electrical current. .
installation instructions 3-wire ' receptacle (NEMA type 10-30R) -_ __ 30 AMP ',, ,_ ELECTRICAL SHOCK HAZARD - \ ' \ NEMA 10-30 _- _,, -: : Neutral /(center wire) Failure to disconnect power source before servicing could result in personal injury or even death. Turn off power supply to outlet• 1• 2. _ ,"_-J_S Remove the screw securing the terminal block access cover in the lower corner on the back of ___--AocessoeVe,sorew _ -. F T_rminal the dryer.
Installation instructions i 4-wire receptacle I I (NEMA type 14-30R) --Neutral WHITE w_re) '_!_ ELECTRICAL SHOCK } N3MOAA I_P30 -____/(GRGEELNnd,re) HAZARD Failure to disconnect power source before servicing could result in personal injury or even death. 1. Turn off power supply to outlet. 2. Remove the screw securing the terminal block access cover in the lower corner on the back of 3. 4. 5. 6. 7. 8.
'"l installation 1. instructions Remove the shipping cap from gas pipe at the rear of the dryer. . Open the shutoff valve in the gas supply line to allow gas to flow through the pipe. Wait a few minutes for gas to move through the gas line. DO NOT connect the dryer to LR gas service without converting the gas valve. An LR conversion kit must be installed by a qualified gas technician. . Connect a 1/2 inch (1.27 cm) I.D. semi-rigid or approved pipe from gas supply line to the 3/8 inch (0.
Installation Water . 2. connection (Steam Model instructions only} Turn off COLD water supply to washer, Remove COLD inlet hose from COLD water supply and inspect for rubber washer. Replace washer if it is torn or worn out. RUBBER WASHER MUST BEPRESENT AND UNDAMAGED J COLD INLET HOSE TO WASHER 3. Momentarily turn on COLD supply and run some water into a bucket or container to clear any contaminants in the line. 4.
installation . instructions If your installation has room for the COLD water supply to accept the "Y" connector directly, thread the "Y" connector to the COLD water supply and snug it by hand; then tighten it another 2/3 turn with pliers. If you were able to install the "Y" connector directly to the COLD water supply, please skip to step 8. 2. If there is not room to install the "Y" connector 3.
Installation , instructions Connect the exhaust duct to the outside exhaust system (see pages 5 through 7). Use of a 4" (10.2 cm) clamp is recommended to connect the dryer to the exhaust vent system. Use metal foil tape to seal all other joints. , Carefully slide the dryer to its final position. Adjust one or more of the legs until the dryer is resting solidly on all four legs. Place a level on top of the dryer. The dryer MUST be level and resting solidly on all four legs.
installation instructions FIRE HAZARD Before operating the dryer, make sure the dryer area is clear and free of combustible materials, gasoline, and other flammable vapors, Also see that nothing (such as boxes, clothing, etc.) obstructs the flow of combustion and ventilation air. - On gas dryers, before the burner will light, it is necessary for the gas line to be bled of a_r.If the burner does not light within 45 seconds the first time the dryer is turned on, the safety switch will shut the burner off.
Reversing Door 1 Be sure you have adequate swing area before reversing door. Tools needed: 2 3 You will need a screw driver with a #2 square bit. Protect flat work surface, such as top of dryer or floor near dryer, with a soft cloth or towel. _ _i_,_-\ \ 4 Be sure dryer is unplugged from power source! //'_'_\ 1'___) ___j-/ Screwdrwers with #2 square & straight bit ELECTRICAL SHOCK HAZARD Failure to disconnect power source before serwcing could result in personal injury or even death.
Reversing Reversing door C) Reversing Hardware Door on Front Panel 1 Remove 2 short, course-thread, panhead screws from striker and 2 plastic hole plugs. Rotate striker and move to opposite opening. Attach with 2 short, course-thread, panhead screws. 3 Install original plastic hole plugs or use new plugs supplied with dryer. D) Removing Door Hardware 1 Remove 2 long, course-thread, counter-sunk screws and latch plate. Set latch aside. Remove 4 long, course-thread, recessed screws and hinge.
Reversing E) Removing F) Removing Latch Indicator Door Hole Plug / _J jj/J jf Insert flat blade screwdriver latch indicator. 2 3 into open slot of Gently pry upward to release tab. Pull the indicator out and set it aside. 1 Insert flat blade screwdriver hole plug. into open slot of 2 Gently pry upward to release tab. 3 Pull the hole plug out and set it aside.
Reversing G) Reinserting Door Latch Indicator 1 Rotate the latch indicator and move it to the opposite hole in the door. H) Reinserting 2 insert indicator Hole Plug 1 Rotate the hole plug and move it to the opposite hole in the door. Firmly insert the two small tabs on either side of the hole plug into the two slots on either side of the hole in the door. Ltab 2 Firmly insert the two small tabs on either side of the latch indicator into the two slots on either side of the hole in the door.
Reversing I) Reattaching Latch Plate K) Reattaching 1 Rotate latch plate and move to opposite side of door above indicator. 2 Reattach with 2 long, course-thread, counter-sunk screws. / / \ 2 Install other 2 short, fine-thread, countersunk screws in upper and lower holes of hinge side. 3 Install 2 short, course-thread, panhead screws through face of hinge plate. 4 Close door and test operation of latch. Hinge 1 Rotate hinge and move to opposite side of door above hole plug.
Reversing Door L) Reversing Trim Ring M) Reinstalling Trim Ring 1 Trim ring orientation is marked on the back. 1 Close door. 2 2 Orient trim so 12 position is approximately 3/4"to the left of top center. Opening in ring should be on the hinge side. 3 Insert trim ring in slots and rotate clockwise approximately 3/,,,. Remove trim ring cover plate. To remove plate from left, pivot point is down. To remove plate from right, pivot point is up.
Options MATCHING STORAGE PEDESTAL Island White Pedestal- P/N EPWD151W Mediterranean Blue - P/N EPWD15MB Silver Sands Pedestal - P/N EPWD15SS Turquoise Sky Pedestal - P/N EPWD15TS A storage pedestal accessory, specifically designed for this dryer may be used to elevate the dryer for ease of use. This pedestal will add about 15" (38.1cm) to the height of your unit for a total height of 53" (134.62 cm). 27 .