The alarms are enabled during the execution of the washing programme, with the exception of alarms
associated with configuration and the power supply (voltage/frequency), which are also displayed during the
programme selection phase.
The door can normally be opened (except where specified) when an alarm condition has occurred on condition
that:
• The level of the water in the tub is below a certain level
• Water temperature lower than 55°C
• Motor stopped
Certain alarm conditions require that a drain phase be performed before the door can be opened for safety
reasons:
• Cooling water fill if the temperature is higher than 65°C
• Drain until the analogue pressure switch is on empty, during a max. 3-minute time.
6.2 Reading the alarm codes
It is possible to display the last three memorised alarms in the FLASH memory of
the electronic board:
• Enter diagnostic mode (par. 5.1).
• Irrespective of the type of PCB and configuration, turn the programme selector
clockwise to the tenth position.
• The last alarm is displayed.
• To display the previous alarms, press button
TEMPERATURE (1) or SPIN (2).