Service manual

SOI/DT 2007-02 dmm 36/66 599 38 61-92
The alarms are enabled during the execution of the washing programme, with the exception of alarms
associated with configuration and the power supply (voltage/frequency), which are also displayed during the
programme selection phase.
The door can normally be opened (except where specified) when an alarm condition has occurred on condition
that:
The level of the water in the tub is below a certain level
Water temperature lower than 55°C
Motor stopped
Certain alarm conditions require that a drain phase be performed before the door can be opened for safety
reasons:
Cooling water fill if the temperature is higher than 65°C
Drain until the analogue pressure switch is on empty, during a max. 3-minute time.
6.2 Reading the alarm codes
It is possible to display the last three memorised alarms in the FLASH memory of
the electronic board:
Enter diagnostic mode (par. 5.1).
Irrespective of the type of PCB and configuration, turn the programme selector
clockwise to the tenth position.
The last alarm is displayed.
To display the previous alarms, press button
TEMPERATURE (1) or SPIN (2).