6.5 Cancelling the memories
To cancel the content of the memories, proceed as follows:
1. Select diagnostic mode and turn the programme selector to the tenth position.
2. Push the OPTIONS 3 and 4 button (as represented in figure).
3. Hold down the buttons till the LCD display shows “Memories have been reset” (at least
5 seconds).
7 OPERATING TIME COUNTER
Using a specific procedure, the operator can display the total operating time for the appliance, which is counted
from the moment it is first switched on.
This option is available only on models equipped with a display
. The unit can count up to a maximum of 6550
hours of operating time.
Only the operating time of normal programmes
(and not diagnostic programmes) is counted
The actual operating time for the cycle is counted (which does not include pauses, delayed start time, time
of a stop with water in the drum, and soaking phases)
The precision of the counter is 30 seconds per programme
Only whole hours of operation
are counted (1 hr and 59 min = 1 hr)
1. Switch off the appliance.
2. Press the START/PAUSE and the OK button simultaneously (as represented in
figure).
3. Holding the buttons down, switch on the appliance turning the programme selector of
five positions clockwise.
4. Hold the buttons down till the LCD shows “WORKED HOURS” (at least 5 seconds)
and the display shows the number of the working hours of the appliance.