Installation manual

Page 11
Relay 4
Com
NC
NO
Relay 3
Com
NC
NO
Relay 2
Com
NC
NO
Relay
NC
NO
esident
Telco
Tip
Ring
Tip
Ring
8
9
10
11
12
13
Relay 4
Com
NC
NO
Relay 3
Com
NC
NO
Relay 2
Com
NC
NO
Relay 1
Com
NC
NO
esident
Telco
Tip
Ring
Tip
Ring
8
9
10
11
12
13
Install a 1N4005 diode
or equivalent.
Use 18-22 AWG
Use 18-22 AWG
Note: The maglock
can be connected to
any
of the
4 Relays
.
Do Not use the EL25's power
supply for the Maglock.
Wiring a Door Strike Lock
Wiring a Maglock
Door Strike Lock / Maglock
Door Strike Lock / Maglock
+
Normally Closed
Common
For DC Power:
Install a
1N4005 diode or equivalent.
Note: The door strike
can be connected to
any
of the
4 Relays
.
Normally Open
Common
Do Not use the EL25's power
supply for the Door Strike.
+
DC Power
AC or DC
Power
Do Not overload
the removable
terminal block
connectors. One
wire per hole.
Output Board
(See page 2)
Output Board (See page 2)
For AC Power:
Install a
Siemens S10K30 MOV
(Metal Oxide Varistor)
or equivalent.