Installation manual

Main
Circuit
Board
J400
RG-6
Coaxial
Connector
Wiegand card readers and keypads can be connected to either of
2 optional wiegand modules
that
can be placed in the EL25.
Each wiegand module supports two card readers/keypads.
Some
wiegand card reader/keypads have a sixth blue wire. Do Not connect this blue wire to the EL25.
Insulate this wire from the unit to prevent a short (Refer to instructions supplied with your wiegand
device for more information).
J407 Position J400 Position
RG-6 Coaxial Cable
100 Feet Maximum
Remote Antenna
Wiring a Radio Frequency Module
RF Module / Card Reader / Keypad
RF Module / Card Reader / Keypad
An optional
radio frequency module
and a remote antenna can be installed if
the residents will
access a controlled area with a transmitter.
Refer to instructions supplied with the optional
RF
Module
for more information.
Wiegand Card Reader / Keypad
Avoid any metallic
surface around the
antenna.
RF Module(s) will fit in
J400 as Device 1 and/or J407 as Device 3.
(4 Mounting Screws per Board)
Wiegand Modules will fit in
J400 as Device 1 (J1) and 2 (J2)
and/or
J407 as Device 3 (J1) and 4 (J2).
(4 Mounting Screws per Board)
Card Reader is Wired to Device 1
Main
Circuit
Board
J400
Device 1
Devi
ce
3
J407
P12V
P5V
DATA 0
DATA 1
LED
COM P12V
P5V
DATA 0
DATA 1
LED
COM
J1J2
P12V
P5V
DATA 0
DATA 1
LED
COM P12V
P5V
DATA 0
DATA 1
LED
COM
J1J2
Device 1Device 3 Device 2Device 4
Red Power
Green
White
Brown
Black
Shield
(Attach to the
EL25 ground).
Blue (Insulate this wire).
Use 18-24
AWG
J407
1 Wiegand Module Kit
Part # WOMODKT
1 RF Module Kit
Part # RFMODKT
Page 14