User Manual

18
Visual Status and Self-Test
The CO alarm will self-check itself and give a status update every 50 seconds if
there are any problems.
The status of the Alarm can also be checked on demand by using the test button.
The table below shows the visual status response to both the self-check and on
demand testing.
Monitoring
Summary
Status
Result
Red LED
(Alarm)
Amber LED
(Fault)
Green LED
(Power)
Sounder
Action
Standby
No
visual
or
audible indication
if
unit
is OK
Unit OK
(
Button
Test)
Off Off
On
Ramps
up to full sound
Low
Battery
Off 1 Flash
Off 1 Beep
See
Note
Sensor
Fault
Off 2 Flashes
Off 2 Beeps
Replace
Unit
End
of
Life
(EOL)
Off 3 Flashes
Off 3 Beeps
Replace
Unit
Note* - R
eplace the
batteries
If the Alarms are indicating a fault, pressing the test button will silence the beeps for
a 24 hour period. This is for your convenience and can only be done once.
Maintenance
Clean the outside case by occasionally wiping with a clean damp cloth. Do not use
any cleaning agents, bleaches, detergents or polishes, including those in aerosol
cans. Avoid spraying air fresheners, hair spray, paint or other aerosols near the CO
Alarm. Do not place air fresheners near the unit.