User Manual

29
(4) Ensure there is no source of hydrogen such as batteries being charged (e.g. on
boats or in Uninterruptable Power Supplies (UPS)).
(5) Ensure there is not excessive smoke or fumes from devices such as Egyptian
shisha, hookah or hubbly bubbly pipes, especially those that use coal or charcoal
to heat the tobacco.
(6) If the Alarm is fitted with an RF Module, ensure that there are no problems with
the other RF interconnected Alarms and that all Alarms are housecoded correctly.
(7) Press the test/hush button to silence the alarm.
If the unit continues to sound it is possibly defective and should be replaced (see
section 9 “Getting the CO Alarm Serviced”).
ELK
-6051
Indicator Summary
Normal
Operation
Red
LED
Amber
LED
Green
LED Sounder
Power
Up
1 flash 1 flash 1 flash Off
Standby
Off Off
Off Off
Button Test
(Weekly)
Off Off
Flashing (every
sec)
Temporal full
sound
Unit Sensing CO gas
itself
Flashing (as per table
B)
Off Off
Temporal full
sound
Sensing CO through RF
interconnect
Off
Off Off
Temporal full
sound
Fault
Mod
e
Low Battery
Condition
Off
1
flash (every 50
secs)
Off
1
beep with
flash
Sensor Fault
Condition Off
2
flashes (every 50
secs) Off
2
beeps with
flash
End of Life
Condition
Off
3
flashes (every 50
secs) Off
3
beeps with
flash