Specifications

M1 Control RS-232 ASCII String Protocol Page 29 of 68 Rev. 1.79 July 16, 2009
ttt – Timer 1 value in seconds. Range “000” to “255”
seconds.
TTT – Timer 2 value in seconds. Range “000” to “255”
seconds.
S – Armed State 0=Disarmed
1=Armed Away
2=Armed Stay
3=Armed Stay Instant
4=Armed Night
5=Armed Night Instant
6=Armed Vacation
00 – future use
CC Checksum
Example 1: 0FEE10060120100E5Area 1, Exit 1 Time =
060, Exit 2 Time = 120 seconds started, Armed Away.
Example 2: 0FEE21030254200DD Area 2, Entrance 1
Time = 030, Entrance 2 Time = 254 seconds started,
Armed Stay.
4.16 Email Trigger (EM)
This command allows the triggering of email transmissions from the M1XEP
Ethernet interface. This command originates in the M1 and is sent to the M1XEP
through serial port 0 only. M1 Version 4.2.8 and after.
4.16.1 Send Email Trigger Data (EM)
09 – Length as ASCII hex
EM – Send email trigger command to M1XEP.
DDD – The address of the email message to send. This
corresponds to the email messages that are stored in
the M1XEP Ethernet interface.
00 – future use
CC Checksum
Example: 09EM0010014 Send email message 001 trigger to the M1XEP
Ethernet interface. The M1XEP will then send the email on the Ethernet to the email
address that is associated with the message.